External Wiring Gland - Oval EL0137 Instructions Manual

Table of Contents

Advertisement

Mounting kit 1

5. EXTERNAL WIRING GLAND

In case of TIIS explosionproof type
(1) This totalizer when used as a flameproof instrument uses the cable gland (pressure-tight packing) method of
IEC harmonized standards for the external wirings. Do not use cable glands other than the provided together
with the instrument. The rubber packing is provided with the product according to the finished external
diameter of cable as shown in the table below. Select and assemble the rubber packing which matches with
the external diameter of your cable.
External dimension of applicable cable
Nominal code of
packing
9
10
11
12
13
NOTE: "Applicable torque" is applied to the gland shown in the assembly diagram below.
 115 mm (4.53") 
 100 mm (3.94") 
  70 (2.76") 
Fig. 4.7 Dimensions of metal clamp
Internal diameter of
External diameter of
packing
φ9
φ10
φ11
φ12
φ13
Flat pattern
 24 
 14 
 14 
 42 
 72 
Applicable torque
cable
φ8.1 to φ9.0
φ9.1 to φ10.0
φ10.1 to φ11.0
φ11.1 to φ12.0
φ12.1 to φ13.0
Bended model
             
 56.2 
Mounting kit 2
Pressure tight packing
18.5N・m
KXB-25, 22 ORES
22.0N・m
25.8N・m
30.0N・m
KXB-25, 22 ORE
33.5N・m
E-126-3-E
model code
11

Advertisement

Table of Contents
loading

Table of Contents