ECOTRONIC Plus
S6
DT6-S5>S6
arrangement/Options/DT-Func6...........change setting to "Yes"
arrangement/Options/Thermo.3 ...........change setting to "Yes"
arrangement/adj. values/t-Th3 on .....change value to "60"
arrangement/adj. values/t-Th3 off ....change value to"55"
arrangement/Options/Thermo.4...........change setting to "Yes"
arrangement/adj. values/t-Th4 on .....change value to "58"
arrangement/adj. values/t-Th4 off ...change value to "60"
S3
R3
arrangement/Options/timer 1 ........................................................change setting to "Yes"
arrangement/adj. values/timer 1/t1 on .......................................change value to "06:00"
arrangement/adj. values/timer 1/t1 off .....................................change value to"08:00"
arrangement/adj. values/timer 1/t2 on ......................................change value to"11:30"
arrangement/adj. values/timer 1/t2 off ....................................change value to "13:30"
arrangement/adj. values/timer 1/t3 on ......................................change value to "18:00"
arrangement/adj. values/timer 1/t3 off ....................................change value to "21:00"
arrangement/Options/Thermo. 1 ...................................................change setting to "Yes"
arrangement/adj. values/t-Th1 on ...............................................change value to"50"
Aarrangement/adj. values/t-Th1 off ...........................................change value to "55"
14
|
S5
R6
Th3-S5
Th4-S6
Timer 1
Th1-S3
For the use of a further heat source (e.g. solid fuel boiler),
one or two thermostat functions can be activated additional-
ly to the differential function, in order to allocate a minimum
temperature to the boiler or to limit the maximum store
temperature.
R6
minimum temperature limitation for the boiler
maximum temperature limitation for the store
In order to control a circulation pump, it might be enough
to activate the timer. With the aid of the 3 time frames, the
relay can be switched individually in the morning, at noon
and in the evening. This process can be further optimised by
activating a thermostat function so that - with a sensor in the
circulation line- control is also temperature-dependent.
R3