Procedure 2.3 - Accessing The User Parameter Program - Precor 9.31 Manual

Hide thumbs Also See for 9.31:
Table of Contents

Advertisement

Procedure 2.3 - Accessing the User Parameter Program

This procedure allows you to change the following settings:
Select Units (9.31, 9.33)
Set Max Pause Time
Set Cool Down Time
Set Speed Limit
Procedure
1.
Plug the power cord into the wall outlet, then turn on the treadmill with the circuit breaker.
2.
Refer to diagram 2.1 above and press keys RESET,5,6,7,1 sequentially. Use the numeric
keypad to enter the number sequence. The ARROW keys will step you through the display
modes listed above, allowing you to skip displays or view only specific displays.
3.
The display will momentarily display DIAGS - SET PARAMETERS
4.
SELECT UNITS (9.31, 9.33)
5.
The currently selected measurement unit will then be displayed.
6.
Use the ARROW keys to toggle between U.S. and METRIC.
7.
Press the ENTER key to select the currently displayed measurement unit.
Note: To change the measurements units on a 9.35, Press the METRICS key, select the
measurement unit with the ARROW keys and save the selection with the OK key.
8.
SET MAX PAUSE TIME
9.
Press the OK or ENTER key.
10. Use the ARROW keys to set the maximum pause time between 1 and 10 minutes.
11. Press the ENTER key to select the currently displayed pause time.
12.
SET COOL DOWN TIME
13. Press the OK or ENTER key.
14. Use the ARROW keys to set the COOL DOWN time between 1 and 5 minutes.
15. Press the ENTER key to select the currently cool down time.
9.31, 9.33, 9.35 Treadmill