9.
Place the brush wires in the drive motor cable clamp and fasten the cable clamp to the drive
motor with the hardware removed in step 4. Place the brush wires in the cable clamp on the
lift motor support and loop them to take up extra wire length as shown in the illustration
above.
Spring
10. Reconnect the brush wires to the lower PCA wires.
11. Set the power input panel in its mounting position and fasten it with the hardware removed
in step 3.
12. Replace the treadmill's motor cover.
13. Insert the treadmill's A.C. power cord into the A.C. outlet and set the treadmill's on/off switch
in the "on" position.
14. Thoroughly test all treadmill functions per Section Three.
9.31, 9.33, 9.35 Treadmill
Brush Wire
Ferrule