3.2 Chip Select (JP508)
CS
CS0
CS1
CS2
CS3
CS4
CS5
CS6
3.3 Define graphic controller Operating Mode (JP201, JP202, JP203)
Up to four Jasmine devices can be join one chip select. The size and location of configuration for every
Jasmine is fixed. The size is set to 64 kByte for every Jasmine and the location are specified by Mode
Jumpers (JP201, JP202).
Mode1-0
Jasmine can also act as a 16Bit device from MCU's point of view. The data mode can be set by Jumper
JP203.
Mode2
It is possible to invert the RDY signal (Mode3 = 1). The RDY signal is not inverted with the application of
the CPU-Module (Mode3 = 0).
Mode3
Jumper setting
ON (closed 1-2)
ULB-Interface Chip-Select 0
ON (closed 3-4)
ULB-Interface Chip-Select 1
ON (closed 5-6)
ULB-Interface Chip-Select 2
ON (closed 7-8)
ULB-Interface Chip-Select 3
ON (closed 9-10)
ULB-Interface Chip-Select 4
ON (closed 11-12)
ULB-Interface Chip-Select 5
ON (closed 13-14)
ULB-Interface Chip-Select 6
Jasmine number
Jasmine 0
Jasmine 1
Jasmine 2
Jasmine 3
JP203
1-2
2-3
JP204
5-6
Description
JP202
2-3
2-3
1-2
1-2
Description
32 Bit data mode
16 Bit data mode
Description
RDY not inverted
JP201
2-3
1-2
2-3
1-2
6