CHAPTER 6 GENERAL INSTALLATION INFORMATION
A. Inspect for Shipping Damage
If the appliance is damaged or damage is suspected:
1.Submit a Damage Claim to the Shipper immediately.
2.Inform your dealer at once.
3.Inform Cleveland Range in writing within three (3) days.
Operating this appliance out of level can cause DEATH, INJURY, and EQUIPMENT DAMAGE.
This appliance must be level both front-to-back and side-to-side in all installations.
If this appliance is suspected to be out of level, shut it down at once and call your qualified
Cleveland Range authorized service agency immediately.
B.
G
CW
NEVER operate this appliance out of level.
D
TW
P
Key to Connections
GAS, 1/2" NPT
G
DRAIN, 1 1/4" NPT
D
CW
COLD WATER, 3/4" Garden Hose
TW
TREATED WATER, 3/4" Garden Hose
P
ELECTRICITY
Cord NOT included.
Connect electricity per local
code.
Do not use a GFCI (GFI).
Note: The utility connections are on the
back of the appliance.
Note: The Descale Port is on top of the
appliance. See Figure 2-1.
Figure 2-2
24CGA10
Utility Locations
12