Connecting To A Converter - Siemens SIMOTICS S-1FK7 Operating Instructions Manual

2nd generation synchronous motors
Table of Contents

Advertisement

5.4.2

Connecting to a converter

Selecting and connecting the cables
• To connect the motor to a converter, use MOTION-CONNECT cables or shielded
connecting cables.
Note
The cable shielding, made up of as many strands as possible, must have a high electrical
conductivity. Braided shields made of copper or aluminum are well suited.
Connection scheme for the motor to the S120 Power Module and Motor Module
Booksize and Compact with a MOTION CONNECT cable
For M23 connector
1
2
3
4
5
6
7
1FK7 G2 synchronous motors
Operating Instructions, 05/2021, A5E50907562B AA
Connector, M23
SPEED CONNECT connector, M23
Terminal for the cable shield
Pin assignment
Circuit diagram
Cable shield
Conductor designation:
U, V, W = power cables, 1.5 mm
BD1+ and BD2- = brake cable without lettering, 1.5 mm
PE = protective conductor
, each cable separately shielded
2
, shared shield
2
Connecting
5.4 System integration
79

Advertisement

Table of Contents
loading