Page 1
Installation and operating instructions GAS FRYERS FOR PROFESSIONAL USE F18-94G F2/18-98G F25-94G F2/25-98G F13T-94G F2/13T-98G F2/8-94G F2/8T-94G Model LIBR.ISTR.F90G Code 563008802 Review 1 Edition date 10/09/2018 Language English LOTUS S.p.A. Via Calmaor, 46 31020 San Vendemiano +39 0438 778020 +39 0438 778277...
Contents Contents INTRODUCTION ......................... Installation drawing ........................Components..........................Example installation of the appliance................... GENERAL INFORMATION......................Declaration of compliance......................User information, RAEE Directive on waste electrical and electronic equipment ......Technical data table ........................INSTALLATION........................... Delivery checks ..........................Removing the packaging ......................Mechanical installation .........................
INTRODUCTION 1 INTRODUCTION Installation drawing FIG. 1 F…-9G A Data Plate B Electrical connection C Gas connection Translation of the original instructions...
Page 4
INTRODUCTION FIG. 2 F...T... A Data Plate C Gas connection Translation of the original instructions...
INTRODUCTION Components FIG. B 1 Thermostat knob 2 Green indicator light 3 White indicator light 4 Hole for indicator light 5 Oil drain 6 Drain extension 7 Power button 8 Valve 9 Safety thermostat 10 Cap Translation of the original instructions...
Page 6
INTRODUCTION FIG. C MOD F…-T , F2/8-94G A Piezoelectric FIG. D 1 Bracket 2 Pilot light nozzle 3 Extends drainage 4 Ignition spark plug FIG. E Burner air adjustment Translation of the original instructions...
GENERAL INFORMATION 2 GENERAL INFORMATION Declaration of compliance The manufacturer declares that the appliances comply with the requirements of the regulation GAR 2016/426 for the gas part and directive 2014/30/EU,2014/35/EU for the electrical part. Installation must be performed in compliance with current regulations, especially with regard to ventilation of the premises and the exhaust gas evacuation system.
Technical data Table F S90G RATED RATED GAS FITTING CAPACITY TANK CAPACITY MODEL DIMENSIONS CAPACITY ISO 7-1 TOTAL Electrical TOTAL Gas KW (230 V~) F18-94G 40x90x90h R 3/4 GM 0,005 F25-94G 40x90x90h R 3/4 GM 0,005 F2/18-98G 80x90x90h R 3/4 GM 0,01 18+18...
INSTALLATION 3 INSTALLATION Delivery checks On delivery, it is important to check the following: · External conditions of the packaging · The general status of the equipment · The conformity of the model with the information in the technical data plate and the instruction manual ·...
Page 12
INSTALLATION Warning Installation operations, any conversion to other types of gas and start-up must only be performed by qualified personnel, in accordance with current regulations. Gas systems, electrical connections and premises where the appliances are installed must comply with current regulations in the country of installation;...
Page 13
INSTALLATION valve and fast-closing valve. Once installation is complete, make sure that there are no gas leaks from the fittings; to do this, do not use a naked flame but substances that do not cause corrosion, such as solutions of soapy water or leak detectors.
Page 14
INSTALLATION - "A" type devices (see data plate) "A" type appliances must discharge combustion products into appropriate hoods, or similar devices, connected to an efficient fume stack or directly to the outside. (Natural evacuation) Fig. 1 If this is not possible, using an air suction device connected directly to the outside is permitted (Forced Evacuation) Fig.2, having a flow capacity not lower than the value defined in point 4.3 of the UNI-CIG 8723 standard.
Page 15
INSTALLATION 1 Windproof fume stack (fig.3) - Extractor hood (fig.4) 2 Servo system "B11" type appliances are supplied on request with a hood or a hood and windproof fume stack to be assembled and delivered separately. Translation of the original instructions...
INSTRUCTIONS FOR USE 5 INSTRUCTIONS FOR USE General information This appliance must only be used for its expressly intended purpose for cooking or heating food. Any other use is considered improper. The appliance is also intended for industrial use and must only be used by personnel trained for use and aware of the risks that the hot element entails.
INSTRUCTIONS FOR USE · The green indicator light (Fig. B pos. 2) remains on and indicates the presence of the mains power down-line of the switch (see wiring diagram Fig. F); the white indicator light (fig. B pos. 3) shows that the main burners are operating, which remain on until the set temperature is reached, after which the pilot flame remains lit (Fig.
INSTRUCTIONS FOR USE Top appliances bowl emptying · The user is required to have a suitable recipient for emptying the water/oil · Insert the drain tube as shown on the drawing, position the container · Push the safety device upwards against the involuntary openings (A) and move the lever (B) ...
MAINTENANCE 6 MAINTENANCE Routine When using the appliance over time, it is essential to perform regular maintenance to ensure safe operation. We therefore recommend stipulating a service contract. Caution Maintenance must only be performed by specialist personnel in compliance with current ...
MAINTENANCE · Replace the nozzle with the appropriate version and make sure that, after ignition, the flame correctly touches the tip of the thermocouple Warning After conversion to another type of gas, update the technical data plate to indicate the type of ...
CLEANING 7 CLEANING Routine cleaning Caution The use of flammable fluids to clean the appliance is forbidden To ensure hygiene and the durability of the appliance, perform external cleaning on a regular basis, taking care not to damage the cables and the electrical connections. Before starting cleaning, disconnect the appliance from the power supply.