Lotus F18-74GVP Installation And Operating Instructions Manual

Professional gas fryer

Advertisement

Quick Links

Installation and operating instructions
PROFESSIONAL GAS FRYER
F13-74G F2/13-78G F18-74G F2/18-78G
F13T-74G F2/13T-78G
F2/8-74G F2/8T-74G
F18-74GVP F2/18-78GVP
Model LIBR.ISTR.F70G CAMINO ALTO
Code 5630068A0
Review 1
Edition date 07/11/2018
Language English
LOTUS S.p.A.
Via Calmaor, 46
31020 San Vendemiano
+39 0438 778020
+39 0438 778277
Translation of the original instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the F18-74GVP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lotus F18-74GVP

  • Page 1 Installation and operating instructions PROFESSIONAL GAS FRYER F13-74G F2/13-78G F18-74G F2/18-78G F13T-74G F2/13T-78G F2/8-74G F2/8T-74G F18-74GVP F2/18-78GVP Model LIBR.ISTR.F70G CAMINO ALTO Code 5630068A0 Review 1 Edition date 07/11/2018 Language English LOTUS S.p.A. Via Calmaor, 46 31020 San Vendemiano +39 0438 778020...
  • Page 2: Table Of Contents

    Contents Contents INTRODUCTION ......................... Installation drawing ........................Components..........................Example installation of the appliance................... GENERAL INFORMATION......................Declaration of compliance......................Technical data table ........................INSTALLATION........................... Delivery checks ..........................Removing the packaging ......................Mechanical installation ......................... Electrical/gas connections ......................BURNERS TECHNICAL DATA TABLE (ITGB)................INSTRUCTIONS FOR USE......................
  • Page 3: Introduction

    INTRODUCTION 1 INTRODUCTION Installation drawing FIG. 1 F13-74G, F2/13-78G, F18-74G, F2/18-78G A Data Plate C Gas connection Translation of the original instructions...
  • Page 4 INTRODUCTION FIG. 2 F2/8-74G, F18-74GVP, F2/18-78GVP FIG. 3 F13T-74G, F2/13T-78G, F2/8T-74G A Data Plate C Gas connection Translation of the original instructions...
  • Page 5: Components

    INTRODUCTION Components FIG. A 1 Gas inlet 2 Ramp 3 Injector 4 Burner {MRK:3} Safety thermostat 6 Air adjustment 7 Knob 8 Extends drainage 9 Pilot 10 Ignition spark plug 11 Oil drain 12 Gas pipes 13 Valve 14 Piezoelectric  ...
  • Page 6 INTRODUCTION FIG. B CLEAN TANK MODELS F18-74GVP F2/18-78GVP 1 Valve 2 Piezoelectric 3 Hole for indicator light 4 Oil drain 5 Drain extension 6 Cap 7 Safety thermostat Translation of the original instructions...
  • Page 7 INTRODUCTION FIG. C A Piezoelectric   FIG. D 1 Bracket 2 Pilot light nozzle 3 Extends drainage 4 Ignition spark plug   FIG. E Burner air adjustment Translation of the original instructions...
  • Page 8 INTRODUCTION FIG. F MODELS WITH CLEAN TANK F18-74GVP F2/18-78GVP Burner air adjustment   FIG. G MODELS WITH CLEAN TANK F18-74GVP F2/18-78GVP 1 Bracket 2 Pilot light nozzle 3 Ignition spark plug 4 Extends drainage   Translation of the original instructions...
  • Page 9: Example Installation Of The Appliance

    INTRODUCTION Example installation of the appliance Translation of the original instructions...
  • Page 10: General Information

    GENERAL INFORMATION 2 GENERAL INFORMATION Declaration of compliance The manufacturer declares that the appliances comply with the requirements of the regulation GAR 2016/426 for the gas part and directive 2014/30/EU,2014/35/EU for the electrical part. Installation must be performed in compliance with current regulations, especially with regard to ventilation of the premises and the exhaust gas evacuation system.
  • Page 11: Technical Data Table

    R ½GM F2/13T-78G 80x70x29h R ½GM 13+13 F2/8-74G 40x70x90h R ½GM F2/8T-74G 40x70x29h R ½GM F18-74GVP 40x70x29h R 3/4 GM F2/18-78GVP 80x70x29h R 3/4 GM 18+18   Technical data table F S70G (maximum load for tank) MAXIMUM LOAD FOR MODEL...
  • Page 12: Installation

    INSTALLATION 3 INSTALLATION Delivery checks On delivery, it is important to check the following:   · External conditions of the packaging · The general status of the equipment · The conformity of the model with the information in the technical data plate and the instruction manual ·...
  • Page 13 INSTALLATION Installation operations, any conversion to other types of gas and start-up must only be   performed by qualified personnel, in accordance with current regulations.   Gas systems, electrical connections and premises where the appliances are installed must comply with current regulations in the country of installation;...
  • Page 14 INSTALLATION   For burners equipped with air adjustment, set the adjustable bushing and lock it with a screw. The "Burner technical data" table shows approximate values for the "h" parameter (primary air). The primary air flow volume must be adjusted to avoid a flame cut-off when the burner is cold and a flame blowback when the burner is hot.
  • Page 15: Burners Technical Data Table (Itgb)

    BURNERS TECHNICAL DATA TABLE (ITGB) 4 BURNERS TECHNICAL DATA TABLE (ITGB) 12.68 kWh/KG 12.87 kWh/KG 9.45 kWh/m3st.   BUTANE PROPANE METHANE H 30 mbar 37 mbar 20 mbar F13-74G       Burner injector 1/100 mm 2 x 110 2 x 110 2 x 170 Pilot injector 1/100 mm Consumption...
  • Page 16 12.68 kWh/KG 12.87 kWh/KG 9.45 kWh/m3st.   BUTANE PROPANE METHANE H 30 mbar 37 mbar 20 mbar F18-74GVP       Burner injector 1/100 mm 2 x 145A 2 x 145A 2 x 225A Pilot injector 1/100 mm 1 x 19...
  • Page 17: Instructions For Use

    INSTRUCTIONS FOR USE 7 INSTRUCTIONS FOR USE General information This appliance must only be used for its expressly intended purpose for cooking or heating food. Any other use is considered improper. The appliance is also intended for industrial use and must only be used by personnel trained for use and aware of the risks that the hot element entails.
  • Page 18: Starting The Main Burner And Adjusting The Temperature

    INSTRUCTIONS FOR USE Starting the main burner and adjusting the temperature · After releasing the knob the gas enters the safety valve · By turning the graduated knob from 110° to 190°C, the gas flows to the main burner which ignites Switching the main burner off ·...
  • Page 19: Top Appliances Bowl Emptying

    INSTRUCTIONS FOR USE Caution Emptying must be carried out when the oil is cold, by inserting an oil drain extension supplied   with the unit, fig. B pos.5, only after the oil collection container of sufficient capacity has been positioned. The oil container can be supplied on request.  ...
  • Page 20 INSTRUCTIONS FOR USE · · This operation must be carried out with liquid that is not excessively hot   Warning Pay close attention to the distance between the appliance and the edges of the support     Translation of the original instructions...
  • Page 21: Maintenance

    MAINTENANCE 8 MAINTENANCE Routine When using the appliance over time, it is essential to perform regular maintenance to ensure safe operation. We therefore recommend stipulating a service contract.   Caution Maintenance must only be performed by specialist personnel in compliance with current  ...
  • Page 22: Spare Parts

      · IGNITION SPARK PLUG (fig.D pos.4); unscrew the coupling, remove and replace the damaged part.   For clean tank models (F18-74GVP and F2/18-78GVP):   · VALVE (fig. B pos. 1) · THERMOCOUPLE (fig. G pos. 4) ·...
  • Page 23: Cleaning

    CLEANING 9 CLEANING Routine cleaning Caution The use of flammable fluids to clean the appliance is forbidden     To ensure hygiene and the durability of the appliance, perform external cleaning on a regular basis, taking care not to damage the cables and the electrical connections. Before starting cleaning, disconnect the appliance from the power supply.