Installation and operating instructions PROFESSIONAL GAS FRYER F13-74G F2/13-78G F18-74G F2/18-78G F13T-74G F2/13T-78G F2/8-74G F2/8T-74G Model LIBR.ISTR.F70G CAMINO ALTO Code 563006802 Review 1 Edition date 07/11/2018 Language English LOTUS S.p.A. Via Calmaor, 46 31020 San Vendemiano +39 0438 778020 +39 0438 778277...
Contents Contents INTRODUCTION ......................... Installation drawing ........................Components..........................Example installation of the appliance................... GENERAL INFORMATION......................Declaration of compliance......................Technical data table ........................INSTALLATION........................... Delivery checks ..........................Removing the packaging ......................Mechanical installation ......................... Electrical/gas connections ......................BURNERS TECHNICAL DATA TABLE (ITGB)................INSTRUCTIONS FOR USE......................
INTRODUCTION 1 INTRODUCTION Installation drawing FIG. 1 F13-74G, F2/13-78G, F18-74G, F2/18-78G A Data Plate C Gas connection Translation of the original instructions...
Page 4
INTRODUCTION FIG. 2 F2/8-74G FIG. 3 F13T-74G, F2/13T-78G, F2/8T-74G A Data Plate C Gas connection Translation of the original instructions...
INTRODUCTION Components FIG. A 1 Gas inlet 2 Ramp 3 Injector 4 Burner 5 Safety thermostat 6 Air adjustment 7 Knob 8 Extends drainage 9 Pilot 10 Ignition spark plug 11 Oil drain 12 Gas pipes 13 Valve 14 Piezoelectric Translation of the original instructions...
Page 6
INTRODUCTION FIG. C A Piezoelectric FIG. D 1 Bracket 2 Pilot light nozzle 3 Extends drainage 4 Ignition spark plug FIG. E Burner air adjustment Translation of the original instructions...
GENERAL INFORMATION 2 GENERAL INFORMATION Declaration of compliance The manufacturer declares that the appliances comply with the requirements of the regulation GAR 2016/426 for the gas part and directive 2014/30/EU,2014/35/EU for the electrical part. Installation must be performed in compliance with current regulations, especially with regard to ventilation of the premises and the exhaust gas evacuation system.
GENERAL INFORMATION Technical data table Technical data table F S70G RATED GAS FITTING TANK CAPACITY MODEL DIMENSIONS TOTAL GAS ISO 7-1 (lt) FLOW (kW) F13-74G 40x70x90h R ½GM F2/13-78G 80x70x90h R ½GM 18,6 13+13 F18-74G 40x70x90h R ½GM 13,5 F2/18-78G 80x70x90h R ½GM...
INSTALLATION 3 INSTALLATION Delivery checks On delivery, it is important to check the following: · External conditions of the packaging · The general status of the equipment · The conformity of the model with the information in the technical data plate and the instruction manual ·...
Page 11
INSTALLATION Installation operations, any conversion to other types of gas and start-up must only be performed by qualified personnel, in accordance with current regulations. Gas systems, electrical connections and premises where the appliances are installed must comply with current regulations in the country of installation;...
Page 12
INSTALLATION For burners equipped with air adjustment, set the adjustable bushing and lock it with a screw. The "Burner technical data" table shows approximate values for the "h" parameter (primary air). The primary air flow volume must be adjusted to avoid a flame cut-off when the burner is cold and a flame blowback when the burner is hot.
Page 13
INSTALLATION Forced evacuation (fig.4) The gas supply to the appliance must be directly servo-controlled by the forced evacuation system and must stop if the flow rate drops below the values indicated in point 4.3 of the UNI-CIG 8723 standard. Resetting the gas supply to the appliance must be possible only by hand.
INSTRUCTIONS FOR USE 5 INSTRUCTIONS FOR USE General information This appliance must only be used for its expressly intended purpose for cooking or heating food. Any other use is considered improper. The appliance is also intended for industrial use and must only be used by personnel trained for use and aware of the risks that the hot element entails.
INSTRUCTIONS FOR USE · Turn the graduated valve knob to the star position . In this position only the pilot flame remains lit Switching the appliance off · Press and turn the knob to position "0". This control blocks the gas supply to both the main burner and the pilot burner ...
INSTRUCTIONS FOR USE Top appliances bowl emptying · The user is required to have a suitable recipient for emptying the water/oil · Insert the drain tube as shown on the drawing, position the container · Push the safety device upwards against the involuntary openings (A) and move the lever (B) ·...
MAINTENANCE 6 MAINTENANCE Routine When using the appliance over time, it is essential to perform regular maintenance to ensure safe operation. We therefore recommend stipulating a service contract. Caution Maintenance must only be performed by specialist personnel in compliance with current ...
MAINTENANCE · Replace the nozzle with the appropriate version and make sure that, after ignition, the flame correctly touches the tip of the thermocouple Warning After conversion to another type of gas, update the technical data plate to indicate the type of ...
CLEANING 7 CLEANING Routine cleaning Caution The use of flammable fluids to clean the appliance is forbidden To ensure hygiene and the durability of the appliance, perform external cleaning on a regular basis, taking care not to damage the cables and the electrical connections. Before starting cleaning, disconnect the appliance from the power supply.