Installation and operating instructions GAS FRYERS FOR PROFESSIONAL USE F18-94G F2/18-98G F25-94G F2/25-98G F13T-94G F2/13T-98G F2/8-94G F2/8T-94G F23-94GVP F2/23-98GVP Model LIBR.ISTR.F90G Code 5630088A0 Review 1 Edition date 10/09/2018 Language English LOTUS S.p.A. Via Calmaor, 46 31020 San Vendemiano +39 0438 778020...
Contents Contents INTRODUCTION ......................... Installation drawing ........................Components..........................Example installation of the appliance................... GENERAL INFORMATION......................Declaration of compliance......................User information, RAEE Directive on waste electrical and electronic equipment ......Technical data table ........................INSTALLATION........................... Delivery checks ..........................Removing the packaging ......................Mechanical installation .........................
INTRODUCTION 1 INTRODUCTION Installation drawing FIG. 1 F…-9G A Data Plate B Electrical connection C Gas connection Translation of the original instructions...
Page 4
INTRODUCTION FIG. 2 F...T... A Data Plate C Gas connection Translation of the original instructions...
INTRODUCTION Components FIG. A MODELS WITH CLEAN TANK F23-94GVP F2/23-98GVP 1 Valve 2 Piezoelectric 3 Hole for indicator light 4 Oil drain 5 Drain extension 6 Cap 7 Safety thermostat Translation of the original instructions...
Page 6
INTRODUCTION FIG. B 1 Thermostat knob 2 Green indicator light 3 White indicator light 4 Hole for indicator light 5 Oil drain 6 Drain extension 7 Power button 8 Valve 9 Safety thermostat 10 Cap Translation of the original instructions...
Page 7
INTRODUCTION FIG. C MODELS F13T-94G F2/13T-98G F2/8-94G F2/8T-94G F23-94GVP F2/23-98GVP A Piezoelectric FIG. D 1 Bracket 2 Pilot light nozzle 3 Extends drainage 4 Ignition spark plug FIG. E Burner air adjustment Translation of the original instructions...
Page 8
INTRODUCTION FIG. F MODELS WITH CLEAN TANK F23-94GVP F2/23-98GVP Burner air adjustment FIG. G MODELS WITH CLEAN TANK F23-94GVP F2/23-98GVP 1 Bracket 2 Pilot light nozzle 3 Ignition spark plug 4 Extends drainage Translation of the original instructions...
Page 9
INTRODUCTION WIRING DIAGRAM (IGNITION) F18-94G ,F2/18-98G , F25-94G , F2/25-98G 1 Ignition spark plug 2 Burner ignition control unit 3 Switch 4 Power supply terminal board WIRING DIAGRAM F18-94G ,F2/18-98G , F25-94G , F2/25-98G 1 Thermostat 2 Green indicator light 3 White indicator light 4 Power supply terminal board 5 Switch...
GENERAL INFORMATION 2 GENERAL INFORMATION Declaration of compliance The manufacturer declares that the appliances comply with the requirements of the regulation GAR 2016/426 for the gas part and directive 2014/30/EU,2014/35/EU for the electrical part. Installation must be performed in compliance with current regulations, especially with regard to ventilation of the premises and the exhaust gas evacuation system.
GENERAL INFORMATION User information, RAEE Directive on waste electrical and electronic equipment With regard to the regulatory framework of reference of the European Community, we remind the user of the following: · Used AAE (Electrical and Electronic Equipment) products must be collected separately ·...
Page 13
GENERAL INFORMATION Technical data table F S90G (maximum load for tank) MAXIMUM LOAD FOR MODEL PRODUCTIVITY (Kg/h) TANK (Kg) F18-94G F25-94G F2/18-98G 15 + 15 F2/25-98G 22 + 22 F13T-94G F2/13T-98G 10 + 10 F2/8-94G 6 + 6 F2/8T-94G 6 + 6 F23-94GVP F2/23-98GVP 22 + 22...
INSTALLATION 3 INSTALLATION Delivery checks On delivery, it is important to check the following: · External conditions of the packaging · The general status of the equipment · The conformity of the model with the information in the technical data plate and the instruction manual ·...
Page 15
INSTALLATION Warning Installation operations, any conversion to other types of gas and start-up must only be performed by qualified personnel, in accordance with current regulations. Gas systems, electrical connections and premises where the appliances are installed must comply with current regulations in the country of installation;...
Page 16
INSTALLATION valve and fast-closing valve. Once installation is complete, make sure that there are no gas leaks from the fittings; to do this, do not use a naked flame but substances that do not cause corrosion, such as solutions of soapy water or leak detectors.
Page 17
INSTALLATION - "A1" type devices (see data plate) "A" type appliances must discharge combustion products into appropriate hoods, or similar devices, connected to an efficient fume stack or directly to the outside. (Natural evacuation) Fig. 1 If this is not possible, using an air suction device connected directly to the outside is permitted (Forced Evacuation) Fig.2, having a flow capacity not lower than the value defined in point 4.3 of the UNI-CIG 8723 standard.
BURNERS TECHNICAL DATA TABLE (ITGB) 4 BURNERS TECHNICAL DATA TABLE (ITGB) 12.68 kWh/KG 12.87 kWh/KG 9.45 kWh/m3st. BUTANE PROPANE METHANE H 30 mbar 37 mbar 20 mbar F18-94G Burner injector 1/100 mm 3 x 115 3 x 115 3 x 170 Pilot injector 1/100 mm 1 x 30...
Page 19
BURNERS TECHNICAL DATA TABLE (ITGB) Technical data table - Burner F S90G CLEAN BATHTUB 12.68 kWh/KG 12.87 kWh/KG 9.45 kWh/m3st. BUTANE PROPANE METHANE H 30 mbar 37 mbar 20 mbar F23-94GVP Burner injector 1/100 mm 2 x160 2 x160 2 x 250 Pilot injector 1/100 mm...
INSTRUCTIONS FOR USE 7 INSTRUCTIONS FOR USE General information This appliance must only be used for its expressly intended purpose for cooking or heating food. Any other use is considered improper. The appliance is also intended for industrial use and must only be used by personnel trained for use and aware of the risks that the hot element entails.
INSTRUCTIONS FOR USE · The green indicator light (Fig. B pos. 2) remains on and indicates the presence of the mains power down-line of the switch (see wiring diagram Fig. F); the white indicator light (fig. B pos. 3) shows that the main burners are operating, which remain on until the set temperature is reached, after which the pilot flame remains lit (Fig.
INSTRUCTIONS FOR USE Starting the main burner and adjusting the temperature · After releasing the knob the gas enters the safety valve · By turning the graduated knob from 110° to 190°C, the gas flows to the main burner which ignites Switching the main burner off ·...
INSTRUCTIONS FOR USE Note Pay close attention to the distance between the appliance and the edges of the basin. 7.12 Top appliances bowl emptying · The user is required to have a suitable recipient for emptying the water/oil · Insert the drain tube as shown on the drawing, position the container ·...
MAINTENANCE 8 MAINTENANCE Routine When using the appliance over time, it is essential to perform regular maintenance to ensure safe operation. We therefore recommend stipulating a service contract. Caution Maintenance must only be performed by specialist personnel in compliance with current ...
MAINTENANCE · Replace the nozzle with the appropriate version and make sure that, after ignition, the flame correctly touches the tip of the thermocouple Warning After conversion to another type of gas, update the technical data plate to indicate the type of ...
CLEANING 9 CLEANING Routine cleaning Caution The use of flammable fluids to clean the appliance is forbidden To ensure hygiene and the durability of the appliance, perform external cleaning on a regular basis, taking care not to damage the cables and the electrical connections. Before starting cleaning, disconnect the appliance from the power supply.