Summary of Contents for Lotus LIBR.ISTR.S90D F-ETT
Page 1
Installation and operating instructions ELECTRIC FRYERS FOR PROFESSIONAL USE F2/8-94ETT F18-94ETT F25-94ETT F2/18-98ETT F2/25-98ETT Model LIBR.ISTR.S90D F-ETT Code 5630606A0 Review 1 Edition date 15/11/2024 Language English LOTUS S.p.A. Via Calmaor, 46 31020 San Vendemiano +39 0438 778020 +39 0438 778277...
Contents Contents INTRODUCTION ......................... Installation drawing ........................Example installation of the appliance................... GENERAL INFORMATION......................Declaration of compliance......................User information, RAEE Directive on waste electrical and electronic equipment ......Technical data table ........................INSTALLATION........................... Delivery checks ..........................Removing the packaging ......................Mechanical installation .........................
INTRODUCTION 1 INTRODUCTION Installation drawing FIG. 1 F..90ETT A Data Plate B Electrical connection D Energy saving connection Translation of the original instructions...
Page 4
INTRODUCTION FIG. A WIRING DIAGRAM F..90ETT 400V~3N 50/60 Hz Translation of the original instructions...
Page 5
INTRODUCTION Electrical technical data table Three-phase power supply terminal block Power switching terminal block Single-pole switch Transformer Contactor Microswitch Resistance switching terminal block Optimiser connection Digital control board Resistance K-type thermocouple temperature probe Safety thermostat FIG.A FIG.A MODELS Terminal board no.1 Terminal board no.2 F2/8-94ETT A + A...
GENERAL INFORMATION 2 GENERAL INFORMATION Declaration of compliance The manufacturer declares that the appliances comply with the requirements of the regulation GAR 2016/426 for the gas part and directive 2014/30/EU,2014/35/EU for the electrical part. Installation must be performed in compliance with current regulations, especially with regard to ventilation of the premises and the exhaust gas evacuation system.
GENERAL INFORMATION User information, RAEE Directive on waste electrical and electronic equipment With regard to the regulatory framework of reference of the European Community, we remind the user of the following: · Used AAE (Electrical and Electronic Equipment) products must be collected separately ·...
Page 9
GENERAL INFORMATION DESIGN ASSEMBLY/TRANSFORMATION ELECTRICAL LINKING TERMINAL BLOCK PERNIONS (see technical data table) · POWER SUPPLY CONNECTION · HEATING ELEMENT CONNECTION Translation of the original instructions...
Page 10
GENERAL INFORMATION Table of parameters F-9..ETT PARAMETER Adjustment ID code DESCRIPTION U.M. Resol. field MAX temp. Maximum temperature 50 - 400 °C NTC temperature for cooling Fan temp. setting 0-50 °C fan(s) start-up Enabling of instrument compartment cooling fan(s) start-up: Cooling fan 0=always off 1=always on...
Page 11
GENERAL INFORMATION PARAMETER Adjustment ID code DESCRIPTION U.M. Resol. field Calculation limit of the PID KI constant. % referring to the PID TR (15) and defines the MaxOut PID_I maximum value of the ON time 20 - 80 component, calculated from the Integrative component alone.
INSTALLATION 3 INSTALLATION Delivery checks On delivery, it is important to check the following: · External conditions of the packaging · The general status of the equipment · The conformity of the model with the information in the technical data plate and the instruction manual ·...
INSTALLATION Warning Installation operations, any conversion to other types of gas and start-up must only be performed by qualified personnel, in accordance with current regulations. Gas systems, electrical connections and premises where the appliances are installed must comply with current regulations in the country of installation;...
Page 14
INSTALLATION Caution ALL PARTS THAT GIVE ACCESS TO LIVE PARTS AFTER REMOVAL ARE MARKED WITH THE "WARNING: DANGEROUS VOLTAGE" SYMBOL Translation of the original instructions...
INSTRUCTIONS FOR USE 4 INSTRUCTIONS FOR USE General information This appliance must only be used for its expressly intended purpose for cooking or heating food. Any other use is considered improper. The appliance is also intended for industrial use and must only be used by personnel trained for use and aware of the risks that the hot element entails.
INSTRUCTIONS FOR USE QR CODE USER MANUAL For the user instructions, refer to the 5630613A0ENNN DIGITAL LINE USER MANUAL by scanning the QR CODE below: https://www.lotuscookers.it/documenti_new/libretti/5630613A0ENNN.pdf Emptying the tank The user is required to have a suitable recipient for emptying the oil. This recipient must be made of heat-resistant material and must ensure that, during the emptying stage, the oil does not overflow and does not represent a hazard.
MAINTENANCE 5 MAINTENANCE Routine When using the appliance over time, it is essential to perform regular maintenance to ensure safe operation. We therefore recommend stipulating a service contract. Caution Maintenance must only be performed by specialist personnel in compliance with current regulations and our own instructions.
Page 18
MAINTENANCE Warning MEASURES TO BE TAKEN IF THE APPLIANCE IS NOT TO BE USED FOR A LONG TIME: Close the gas cock and/or disconnect the power supply. Clean the system as specified above. Translation of the original instructions...
CLEANING 6 CLEANING Routine cleaning Caution The use of flammable fluids to clean the appliance is forbidden To ensure hygiene and the durability of the appliance, perform external cleaning on a regular basis, taking care not to damage the cables and the electrical connections. Before starting cleaning, disconnect the appliance from the power supply.