Technical data

7.3
Technical data
Order number
Power supply
Operation voltage
Power consumption
Interface
Interface options
(selected via S7 and S8)
Transmission rate
Number of read/write
heads
Read/write head power sup-
ply
Ambient conditions
Operating temperature
Storage temperature
Humidity
Schutzart nach EN 60529
Interface immunity as in:
Mechanical data
Construction type
Mounting
Vibration resistance when
installed as specified
Housing method
Plammability class
Connections
Subject to reasonable modifications due to technical advances.
34
Pepperl+Fuchs Group • Tel.: Germany (06 21) 7 76-0 • USA (330) 4 25 35 55 • Singapore 7 79 90 91 • Internet http://www.pepperl-fuchs.com
IVI-KHD2-4HRX
18 V DC ... 32 V DC
Residual ripple £ 10 %
max. 5 W
RS 232 or RS 422 or RS 485
TTY 20 mA (current loop) passive
300 ... 19 200 Bit/s
max. 4
120 mA/17,5 V DC ± 5 %
-25 °C to +70 °C (248 to 343 Kelvin)
-25 °C to +85 °C (248 to 358 Kelvin)
max. 75 % relative of air humanidity
IP 20
EN 50081-2 (ermitted interference)
EN 50082-2 (noise immunity)
60 mm terminal housing
Snap-mounted on standard rail to DIN 46277 or
screwed fixing to DIN 43602
To DIN IEC 721 Part 3-5 Class 5M2
Makrolon 6485
UL94
self opening terminals,
max. core cross-section 2x2,5 mm
Built-in 9-pin Sub-D-connector
IVI-KHA6-4HRX
90 V AC ... 253 V AC
50 ... 60 Hz
SS
max. 5 VA
2
Copyright Pepperl+Fuchs, Printed in Germany