The following commands apply to the IMC-40- ... and IDC- ... -1K data carriers:
Read page, Single mode
Command:
Response:
Read page, Auto mode
Command:
Response:
Example:
The following commands apply only to the IMC-40- ... data carriers:
Write page, Single mode
Command:
Response:
Since a complete page is written, the <DB> field must comprise 32 bytes.
Write page, Auto mode
Command:
Response:
Example:

6.2.4 Description of System Commands:

The command header (the first character of the command) may be either upper or
lower case.
Set data carrier type
This command is used to indicate the type of data carrier with which the control inter-
face unit is to communicate. The default setting is the IDC- ... -1K data carrier.
Command:
Response:
<DT>
1
2
3
4
Example: Set data carrier type IMC-40 - ... : Command: d 3 97h 03h
Subject to reasonable modifications due to technical advances.
Pepperl+Fuchs Group • Tel.: Germany (06 21) 7 76-0 • USA (330) 4 25 35 55 • Singapore 7 79 90 91 • Internet http://www.pepperl-fuchs.com
IDENT-I • IVI-KHA6-4HRX, IVI-KHD2-4HRX
l <HdNo><PNr><CHCK><ETX>
l <Status><32DB><CHCK><ETX>
L <HdNo><PNr><CHCK><ETX>
L <Status><32DB><CHCK><ETX>
Page 7 is to be read in auto mode with read head 2:
Command: L 2 007 15h 03h
m <HdNo><PNr><32DB><CHCK><ETX>
m <Status><CHCK><ETX>
M <HdNo><PNr><32DB><CHCK><ETX>
M <Status><CHCK><ETX>
Zeros are to be written on page 7, in auto mode, using read head
2. Command: M 2 007 00h ... (32 times) ... 00h 15h 03h
d <DT><CHCK><ETX>
d <CHCK><ETX>
Data carriers
IDC- ...
reserved
IMC-40- ...
IDC- ... -1K
Commands