Connect Power to a PA-3200 Series Firewall
Connect AC Power to a PA-3200 Series Firewall
The following procedure describes how to connect AC power to a PA-3200 Series firewall with AC
power supplies.
The power configuraon (AC or DC) can be changed in the field. However, you cannot
install both an AC and DC power supply in the same firewall. The firewall ships with AC
power supplies (DC power supplies sold separately).
To avoid injury to yourself or damage to your Palo Alto Networks
that resides on the hardware, read the
STEP 1 |
Remove the two nuts and star washers from the ground studs on the back of the firewall and
then remove the two-post ground lug.
STEP 2 |
Crimp a 6AWG ground cable (not included) to the two-post ground lug and then aach the
ground lug to the ground studs on the firewall. Replace the star washers and nuts and torque
to 25 in-lbs. Connect the other end of the ground cable to earth ground.
STEP 3 |
Connect the AC power cord to power input 1 (PWR 1) and connect a second power cord to
power input 2 (PWR 2).