PaloAlto Networks PA-3200 Series Hardware Reference Manual page 29

Next-gen firewall
Hide thumbs Also See for PA-3200 Series:
Table of Contents

Advertisement

Connect Power to a PA-3200 Series Firewall
the negave terminal. Repeat this step for the second DC power supply using separate
posive and negave cables.
4. Replace the plasc covers over each DC power input.
5. Connect the two posive and two negave DC power cables to your power sources
and ensure that you observe the correct polarity (posive to posive and negave to
negave).
Connect the second set of power cables through a different DC circuit to provide
power redundancy and to allow for electrical circuit maintenance.
STEP 4 |
Aer all DC power cables are securely connected, power on the DC power sources. The
power supplies powers on, the input and output LEDs on the power supplies turn green, and
the PWR LED and the power supply LEDs (PWR 1 and PWR 2) on the front of the firewall
turns green.
PA-3200 Series Next-Gen Firewall Hardware Reference
29
2021 Palo Alto Networks, Inc.
©