Connect Power to a PA-3200 Series Firewall
the negave terminal. Repeat this step for the second DC power supply using separate
posive and negave cables.
4. Replace the plasc covers over each DC power input.
5. Connect the two posive and two negave DC power cables to your power sources
and ensure that you observe the correct polarity (posive to posive and negave to
negave).
Connect the second set of power cables through a different DC circuit to provide
power redundancy and to allow for electrical circuit maintenance.
STEP 4 |
Aer all DC power cables are securely connected, power on the DC power sources. The
power supplies powers on, the input and output LEDs on the power supplies turn green, and
the PWR LED and the power supply LEDs (PWR 1 and PWR 2) on the front of the firewall
turns green.
PA-3200 Series Next-Gen Firewall Hardware Reference
29
2021 Palo Alto Networks, Inc.
©