Polycom RealPresence Immersive Studio User Guide
● A service person must verify that all socket outlets from which the equipment is
to be powered provides a connection to the building protective earth.
To verify, use a suitable long test/wander lead with an ohm meter/multimeter.
Connect one end to a known protective earthing point of the building electrical
installation and ensure that there is a reading of less than one ohm to each
earthing contact of all socket outlets to be connected as shown in
Earthing Contact
Socket Outlets Earthing Contact Points
If lack of protective earth is discovered at any of the socket outlets, this must first
be rectified by installing a suitable protective earthing conductor in accordance
with local wiring code and regulations. This must be carried out by a registered,
competent electrician.
System Rating
Points.
Regulatory Information