Hydro Transaxle Drive Belt Replacement - Toro TIMECUTTER 74685 Service Manual

Hide thumbs Also See for TIMECUTTER 74685:
Table of Contents

Advertisement

Hydro Transaxle Drive Belt Replacement

Hydro Transaxle Drive Belt Removal
TIMECUTTER® Service Manual
3433-938 Rev A
1. Park the machine on a level surface and set the parking brake. Stop the
engine, wait for all moving parts to stop and remove the key.
2. Disconnect the battery by removing the negative battery cable first, then
the positive cable from the battery.
3. Remove 10 (T-40) self-tapping screws securing the rear engine guard and
muffler shield to the chassis. Remove the muffler shield and rear engine
guard.
g300621
4. Remove the deck tensioner spring from the spring hook.
g300623
5. Using an appropriate lifting device, raise the machine. Remove the deck
belt from the clutch pulley.
Figure 222
Figure 223
Page 6–5