THERMOROSSI COMPACT S18 EVO Installation, Use And Maintenance Manual

THERMOROSSI COMPACT S18 EVO Installation, Use And Maintenance Manual

Advertisement

Quick Links

COMPACT S18 EVO
ITA - MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE.
FRA - MANUEL D'INSTALLATION, D'UTILISATION ET ENTRETIEN.
ENG - INSTALLATION, USE AND MAINTENANCE GUIDE.
DEU - INSTALLATIONS-, BETRIEBS- UND WARTUNGSANLEITUNG.
ESP - MANUAL DE INSTALACIÓN USO Y MANTENIMIENTO.
ITA – Informazioni importanti per la sicurezza ed il corretto funzionamento.
FRA - A lire impérativement! Informations importantes pour la sécurité et le bon fonctionnement.
ENG - Must read! Important information for safety and correct operation.
DEU - Unbedingt lesen! Wichtige informationen zur sicherheit und zum sicheren betrieb.
ESP - ¡Leer! Informaciones importantes para la seguridad y el correcto funcionamiento.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the COMPACT S18 EVO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for THERMOROSSI COMPACT S18 EVO

  • Page 1 COMPACT S18 EVO ITA - MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE. FRA - MANUEL D’INSTALLATION, D’UTILISATION ET ENTRETIEN. ENG - INSTALLATION, USE AND MAINTENANCE GUIDE. DEU - INSTALLATIONS-, BETRIEBS- UND WARTUNGSANLEITUNG. ESP - MANUAL DE INSTALACIÓN USO Y MANTENIMIENTO. ITA – Informazioni importanti per la sicurezza ed il corretto funzionamento.
  • Page 2 Installation, use and maintenance guide COMPACT S18 EVO Page 1...
  • Page 3: Table Of Contents

    Installation, use and maintenance guide COMPACT S18 EVO INDEX 1 – INTRODUCTION..........................4 2 – TECHNICAL CHARACTERISTICS...................... 6 3 – GENERAL DESCRIPTION ........................7 4 – INSTALLATION ........................... 9 5 – HYDRAULIC CONNECTION ......................12 6 – USE OF THE APPLIANCE .........................19 7 ADDITIONAL ROOM TEMPERATURE THERMOSTAT / ADDITIONAL CHRONOTHERMOSTAT ..33...
  • Page 4 Installation, use and maintenance guide COMPACT S18 EVO EU Declaration of Conformity (DoC) / Dichiarazione di Conformità UE (DoC) Company name: Postal address: THERMOROSSI S.P.A. VIA GRUMOLO, N° 4 Azienda: Indirizzo: Postcode and city: Telephone number: 36011 ARSIERO (VI) 0445/741310 Codice postale e città:...
  • Page 5: Introduction

    Furthermore, Thermorossi reserves the right to apply changes to the content of this manual anytime and without notice. Thermorossi S.p.A. retains copyright on this manual. These instructions may not be reproduced or communicated to third parties or used in any other way without the necessary authorisation.
  • Page 6 Installation, use and maintenance guide COMPACT S18 EVO ATTENTION: the door must always remain shut tight when the appliance is operating. It is strictly forbidden to open the door while the appliance is in operation. During operation, the smoke exhaust pipes, door, handles and some parts of the appliance may reach extremely high temperatures: be careful not to touch them and also educate children to be aware of said risks.
  • Page 7: Technical Characteristics

    Installation, use and maintenance guide COMPACT S18 EVO 2 – TECHNICAL CHARACTERISTICS COMPACT S18 EVO M.U. VALUES Height 1,380 Depth Width Empty weight Firebox power Min. / Max. * 5.29 / 18.28 Thermal output to water Min / Max * 4.66 / 17.06...
  • Page 8: General Description

    Installation, use and maintenance guide COMPACT S18 EVO 3 – GENERAL DESCRIPTION 3.1 OPERATING TECHNOLOGY Your appliance has been built to fully satisfy all your heating and practical requirements. Top-grade components and functions managed with microprocessor technology guarantee high reliability and optimal performance.
  • Page 9 Installation, use and maintenance guide COMPACT S18 EVO 3.4 MAIN COMPONENTS OF THE BOILER Pellet Power Motor Temperature sensor and reset thermostat bulb Circulating pump Automatic relief valve Smoke suction unit Tube bundle inspection cover Smoke exhaust pipe Control panel...
  • Page 10: Installation

    Installation, use and maintenance guide COMPACT S18 EVO 4 – INSTALLATION 4.1 APPLIANCE LOCATION Follow the general guidelines set out in paragraph 1.1 to the letter. Above all keep in mind that the flooring of the room in which the appliance is being installed must withstand the weight of the stove with the added weight of the pellet load and the water contained in it.
  • Page 11 Installation, use and maintenance guide COMPACT S18 EVO 4.2 UNPACKING THE APPLIANCE The appliance is supplied packaged on a pallet; before positioning and installing it dismantle the appliance from the pallet as described. - Remove the cover and the side panels of the pallet (A) and also the edge protectors (B) (Figure 1).
  • Page 12 Moreover, a suitable windbreak fitting must be installed in the duct’s terminal. Il presente disegno è di proprietà esclusiva di THERMOROSSI S. p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito secondo i termini di legge in vigore. Prodotto...
  • Page 13: Hydraulic Connection

    Installation, use and maintenance guide COMPACT S18 EVO 5 – HYDRAULIC CONNECTION 5.1 HYDRAULIC DIAGRAM System circulating pump 2 l closed expansion tank Automatic relief valve System drain/refill gate valve Boiler water temperature sensor Plant return Reset thermostat bulb Plant delivery...
  • Page 14 Installation, use and maintenance guide COMPACT S18 EVO 5.2 GUIDELINES FOR PLANTS WITH ZONE VALVES El e t t r o v a l v o l a s e m p r e a p e r t a...
  • Page 15 Installation, use and maintenance guide COMPACT S18 EVO 5.3 HYDRAULIC DIAGRAM WITH HEATING ONLY VM3 VT VN R andata impianto riscaldamento ritorno impianto riscaldamento saracinesca VNR : valvola di non ritorno VEC : vaso di espansione chiuso per protezione impianto VM3VT : valvola miscelatrice punto fisso 55°C...
  • Page 16 Installation, use and maintenance guide COMPACT S18 EVO 5.4 EXAMPLE OF HYDRAULIC DIAGRAM WITH INTERSPACED BOILER COILS OR BOILER COILS VM3 VT VN R andata impianto riscaldamento ritorno impianto riscaldamento saracinesca VNR : valvola di non ritorno VEC : vaso di espansione chiuso per protezione impianto VM3VT : valvola miscelatrice termostatica punto fisso 55°c...
  • Page 17 Installation, use and maintenance guide COMPACT S18 EVO 5.5 EXAMPLE OF HYDRAULIC DRAWING WITH BOILER COILS AND HEATING So n d a PT1 0 0 Al l a m o r s e t t i e r a CN 5...
  • Page 18 Installation, use and maintenance guide COMPACT S18 EVO 5.6 HYDRAULIC DIAGRAM WITH THERMOCELL + THERMOPUFFER + HEATING Attenzione : chiudere tutti i fori Attenzione : chiudere tutti i fori Riscaldamento pavimento non usati del puffer non usati del puffer Radiatori Alla morsettiera CN5 °C...
  • Page 19 The nominal volume of the additional closed expansion tank must be sized in relation to the volume of expansion of the water contained in the system. Thermorossi prescribes that the size of the additional closed expansion tank must be equal to 10% of the water contained in the system.
  • Page 20: Use Of The Appliance

    Installation, use and maintenance guide COMPACT S18 EVO 6 – USE OF THE APPLIANCE The appliance, when operating, could be hot to the touch, particularly the door of the combustion chamber: take care when handling the appliance components. Your appliance has obtained the CE marking and has been made to run for at least one hour to check that it functions correctly.
  • Page 21 Installation, use and maintenance guide COMPACT S18 EVO Display The following information can appear on the display: The appliance is in OFF phase. 1° MANUAL OPERATING POWER 2° MANUAL OPERATING POWER 3° MANUAL OPERATING POWER 4° MANUAL OPERATING POWER 5° MANUAL OPERATING POWER In this mode the user can choose to run the appliance from the minimum power (therefore with the minimum pellet consumption) to the maximum power (therefore with the maximum pellet consumption).
  • Page 22 Installation, use and maintenance guide COMPACT S18 EVO 6.2 DESCRIPTION OF THE POWER PANEL The components of the power board are described below: 1) Electrical power outlet 220V-240V 50Hz 2) Main switch 0/I. 3) Test light for pellet feed motor.
  • Page 23 Installation, use and maintenance guide COMPACT S18 EVO 2) Press the Scroll Buttons to select the day of the week on which you want to set the program. Each number corresponds to one day of the week (e.g. 1 corresponds to Monday, 2 corresponds to Tuesday, etc...). To confirm the selected day of the week for the programming press the Degrees Button.
  • Page 24 Installation, use and maintenance guide COMPACT S18 EVO For example: if I want to copy all the programmed ON/OFF cycles set for Monday to Tuesday the following screen will appear: Press the Flame button once again to copy all the cycles programmed for Tuesday to Wednesday. The following screen will appear: Using the same logic we can copy the programmed cycles to the other days.
  • Page 25 Installation, use and maintenance guide COMPACT S18 EVO When is it important to use the CHRONO function? In systems configured like the diagram on the right, where the appliance is connected directly to the system, without the use of external chronothermostats. In this case it is necessary to set the hour programs to prevent the appliance from being stressed by uncontrolled ON and OFF cycles.
  • Page 26 Installation, use and maintenance guide COMPACT S18 EVO After a few seconds the following screen will appear on the display: Press one of the two Scroll Buttons and the following screen will appear (Select ON to activate). Confirm the selection by pressing the Degrees Button and the following screen will appear: Press the Scroll Buttons to set the activation temperature for Sensor S2.
  • Page 27 Installation, use and maintenance guide COMPACT S18 EVO 6.7 ACS SUMMER: ACTIVATION OF THE BOILER TUBE CONTROL FROM A CHRONO COMMAND The appliance must be energised and the I/0 switch in position “I". This function enables you to manage the operating temperature of a boiler tube for the production of domestic hot water (ACS) through the use of a sensor PT 100 (optional) connected to the terminal block on the electronic board.
  • Page 28 Installation, use and maintenance guide COMPACT S18 EVO ATTENTION The boiler tube must have at least a 300 litre capacity. Pay special attention to the number of ON/OFF cycles that the appliance is subjected to with this function. It is recommended not to exceed three ON/OFF cycles.
  • Page 29 Installation, use and maintenance guide COMPACT S18 EVO Pay special attention to the number of ON/OFF cycles that the appliance is subjected to with this function. It is recommended not to exceed three ON/OFF cycles. If the startups are frequent and repeated it is possible that the generator will fail to start and the following error message appear: “Failed start –...
  • Page 30 Installation, use and maintenance guide COMPACT S18 EVO Confirm the selection by pressing the Degrees Button and the following screen will appear. Press the Scroll Buttons to set the maximum activation temperature for the sensor. The sensor commands the appliance to shut off if it is ON, whereas if the appliance is operating, it commands the diverting valve as the boiler tube is satisfied.
  • Page 31 Installation, use and maintenance guide COMPACT S18 EVO When is it important to use the THERMO ACS function together with the TAMBIENT function? In systems configured like the nearby diagram, where the appliance is connected directly to a domestic hot water boiler tube and to the system.
  • Page 32 Potenza di funzionamento funzionamento Intervallo Modulation frequency Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, Prodotto Descrizione modulazione con T with T max 65°C...
  • Page 33 Installation, use and maintenance guide COMPACT S18 EVO 6.11 SWITCHING ON THE APPLIANCE Before using the appliance check that all the movable parts are correctly fitted. Also remove any labels and stickers from the glass to avoid that permanent traces remain on the surfaces. Verify that the electric and hydraulic connections have been made perfectly.
  • Page 34: Additional Room Temperature Thermostat / Additional Chronothermostat

    230 V or lower voltages as this would seriously damage the control board, and is not covered by warranty. ATTENTION: In the event of connections to the chronothermostat Thermorossi shall not be held responsible for the appliance not starting up, smoke leaks, breakage of the lighting component.
  • Page 35 Installation, use and maintenance guide COMPACT S18 EVO Legenda Cronotermostato Modem Chronothermostat - Modem Contatti 9-10 della morsettiera CN7 Contacts 9-10 of the terminal block CN7 Termostato Ambiente Room Temperature Thermostat Contatti 7-8 della morsettiera CN7 Contacts 7-8 of the terminal block CN7...
  • Page 36: Cleaning And Maintenance

    Installation, use and maintenance guide COMPACT S18 EVO 8 - CLEANING AND MAINTENANCE 8.1 FOREWORD Before beginning any maintenance operation ensure that the appliance is switched OFF and disconnected from the electric power socket. Your appliance, being a pellet-fuelled appliance, requires regular general controls and cleaning.
  • Page 37 Installation, use and maintenance guide COMPACT S18 EVO A vacuum device simplifies the ash cleaning procedure. The front and side casings must be cleaned when the heater is cold using a soft cloth and water. It is also normal to find partially or totally unburned pellets in the ash pan. The door of the combustion chamber must only be opened when the appliance has completely cooled down: when it is opened it is normal for some ash to spill onto the floor.
  • Page 38 Installation, use and maintenance guide COMPACT S18 EVO Page 37...
  • Page 39 Installation, use and maintenance guide COMPACT S18 EVO Page 38...
  • Page 40: Smoke Discharge Tube And Ventilation Of The Rooms

    Installation, use and maintenance guide COMPACT S18 EVO 9 – SMOKE DISCHARGE TUBE AND VENTILATION OF THE ROOMS 9.1 FOREWORD Due to the frequent accidents caused by poor functioning of flue outlets installed in private dwellings, we have prepared the following paragraph to assist the installer in his inspection of the parts concerned with eliminating the gases produced by combustion.
  • Page 41 Installation, use and maintenance guide COMPACT S18 EVO The installer must provide one or more access points on the flue outlet to check the emissions once the appliance has been installed; these access points must be made in such a way as to be air-tight sealable to prevent exhaust gas leaks.
  • Page 42 Installation, use and maintenance guide COMPACT S18 EVO 9.3.3 CONTROLS PRIOR TO INSTALLING THE APPLIANCE The user must possess a certificate of conformance for the flue outlet (Ministerial Decree 22 January 2008, no. 37). The flue outlet must be built in compliance with UNI 10683. The smoke exhaust shown in the...
  • Page 43: Alarms

    ATTENTION: The appearance of one of the alarms described below, does not necessarily imply a defect in the product, but simply Thermorossi S.p.A.’s intention to inform the user of the need for corrective actions in order to guarantee maximum safety, greater reliability and high performance of the appliance .
  • Page 44: Electrical Wiring

    Installation, use and maintenance guide COMPACT S18 EVO 11 - ELECTRICAL WIRING To access the electronic board it is necessary to follow the instructions indicated in the above drawings: - Open the tank cover (Figure 1) and remove the top cover by pulling it upwards (Figure 2).
  • Page 45: Information For The Skilled Technician

    Installation, use and maintenance guide COMPACT S18 EVO 12 – INFORMATION FOR THE SKILLED TECHNICIAN 12.1 MAIN COMPONENTS AND THEIR POSITION SMOKE PRESSURE SWITCH This is a safety switch that stops the screw feeder motor whenever necessary. The main cause for the pressure switch tripping is a blocked flue outlet or smoke exhaust pipe.
  • Page 46 Installation, use and maintenance guide COMPACT S18 EVO 12.3 TROUBLESHOOTING CAUSE / SOLUTION PROBLEM POSSIBLE CAUSE SOLUTION PELLET TANK IS EMPTY CLEAN THE BRAZIER AS INDICATED IN THIS USE AND THE “NO PELLET – CLEAN BURNER” ALARM IS SHOWN ON...
  • Page 47 Installation, use and maintenance guide COMPACT S18 EVO PROBLEM POSSIBLE CAUSE SOLUTION ROOM TEMPERATURE THERMOSTAT SET TOO OPERATE FOR LONGER PERIODS OR AT A HIGHER POWER LEVEL LOW, APPLIANCE OPERATES INTERMITTENTLY BY SETTING A HIGHER ROOM TEMPERATURE SURFACE AREA TO HEAT IS TOO BIG OR TOO...
  • Page 48: Spare Parts

    Installation, use and maintenance guide COMPACT S18 EVO 13 - SPARE PARTS 60011282 60011280 70030425 Solo versione stagna 70030424 70027472 Coperchio completo 70030423 Coperchio Completo 70028232 Guarn. completa 70030428 70030409 70030427 70030426 Coperchio completo 70030419 70030407 60011673 60011793 70030421 70020916...
  • Page 49 Installation, use and maintenance guide COMPACT S18 EVO F ire L o v e rs Via Grumolo, 4 (Z.I.) 36011 Arsiero (VI) - ITALY Fax 0445.741657 - www.thermorossi.com - info@thermorossi.it Page 48...

Table of Contents