Download Print this page
THERMOROSSI ECOTHERM 3001 Installation, Use And Maintenance Manual

THERMOROSSI ECOTHERM 3001 Installation, Use And Maintenance Manual

Pellet stove
Hide thumbs Also See for ECOTHERM 3001:

Advertisement

Quick Links

HEATING TECHNOLOGY AND INNOVATION
INSTALLATION, USE AND MAINTENANCE GUIDE
ECOTHERM 3001
ECOTHERM 3001 THERMOCOMFORT
www.thermorossi.com

Advertisement

loading

Summary of Contents for THERMOROSSI ECOTHERM 3001

  • Page 1 HEATING TECHNOLOGY AND INNOVATION INSTALLATION, USE AND MAINTENANCE GUIDE ECOTHERM 3001 ECOTHERM 3001 THERMOCOMFORT www.thermorossi.com...
  • Page 2 Operating with the additional room temperature thermostat (not supplied)...…………..........Operating with the additional chronothermostat (not supplied).................. 7 A. ADDITIONAL ROOM TEMPERATURE THERMOSTAT (not supplied) FOR "ECOTHERM 3001 THERMOCOMFORT" / ADDITIONAL CHRONOTHERMOSTAT (not supplied) FOR "ECOTHERM 3001 THERMOCOMFORT" ..... 7A.1 Operating with the additional room temperature thermostat (not supplied)...…………..........
  • Page 3: Ce Declaration Of Conformity

    92/31/EEC 93/97/EEC Thermorossi S.p.A., Via Grumolo 4 - ARSIERO (VI), declares that the heaters of the ECOTHERM series have been designed and manufactured in compliance with the safety requirements of the standards for EC marking. This declaration refers to the entire range of the specified series.
  • Page 4 Thermorossi s.p.a, will automatically void the warranty and the manufacturer's responsibility, pursuant to D.P.R. 224 of 24/05/1988, art. 6/b . Use only original Thermorossi spare parts. If the appliance is sold or transferred to another user ensure that the guide is handed over with it.
  • Page 5: Technical Characteristics

    Ecotherm 3001 Ecotherm 3001 2 2 2 2 2 TECHNICAL CHARACTERISTICS * TECHNICAL CHARACTERISTICS * TECHNICAL CHARACTERISTICS * TECHNICAL CHARACTERISTICS * TECHNICAL CHARACTERISTICS * Easy-Metalcolor Ceramic element All the data are based on the appliance fuelled with Austrian standard O M 7135 type-approved pellets.
  • Page 6: General Description

    3 3 3 3 3 GENERAL DESCRIPTION GENERAL DESCRIPTION GENERAL DESCRIPTION GENERAL DESCRIPTION GENERAL DESCRIPTION OPERA OPERA OPERA OPERA OPERATING TING TING TING TING TECHNOL TECHNOL TECHNOL TECHNOLOGY TECHNOL •Your heater has been built to fully satisfy all your heating and practical requirements. Top-grade components and functions managed with microprocessor technology guarantee high reliability and optimal performance.
  • Page 7 4.1.2 4.1.2 4.1.2 4.1.2 4.1.2 MOUNTING CERAMIC CASING MOUNTING CERAMIC CASING MOUNTING CERAMIC CASING MOUNTING CERAMIC CASING MOUNTING CERAMIC CASING The next step, after positioning the heater, is to mount the ceramic casing as illustrated in the figures below. Carry out the following operations: - Remove the top cast iron cover ( Figure 1).
  • Page 8 5 5 5 5 5 DESCRIPTION OF ECOTHERM 3001 CONTROLS DESCRIPTION OF ECOTHERM 3001 CONTROLS DESCRIPTION OF ECOTHERM 3001 CONTROLS DESCRIPTION OF ECOTHERM 3001 CONTROLS DESCRIPTION OF ECOTHERM 3001 CONTROLS DESCRIPTION OF GREY HANDHELD RADIO CONTR DESCRIPTION OF GREY HANDHELD RADIO CONTR...
  • Page 9 (3) (4) Auxiliary buttons for temperature setting Press button 3 to lower the temperature. Press button 4 to raise the temperature level set in Aladino. As is explained below they are only functional if the AUTO cycle is selected. The set temperature appears in zone 9 of the display.
  • Page 10 5.1.4 HEA 5.1.4 HEA TER REAR P TER REAR P ANEL ANEL 5.1.4 HEA 5.1.4 HEA 5.1.4 HEATER REAR P TER REAR P TER REAR PANEL ANEL ANEL The rear panel integrates the radio control. A description of the functions of the buttons and LEDs on the rear panel of the heater: (20) Insert on/off and flame adjustment button By pressing this button you can use the heater even without the radio control.
  • Page 11 5.3 ON/OFF PROGRAMMING. 5.3 ON/OFF PROGRAMMING. 5.3 ON/OFF PROGRAMMING. 5.3 ON/OFF PROGRAMMING. 5.3 ON/OFF PROGRAMMING. The heater must be energised and the switch at the back in position "1". The weekly programming can be executed with the help of the handheld radio control.
  • Page 12 5.7 D 5.7 D 5.7 D 5.7 D 5.7 DA A A A A T T T T T A A A A A AN ANAL ALY Y Y Y Y SIS DATA ANALYSIS represents the function concerning update of data between the heater and the handheld radio control. The radio wave transmission is frequently used by numerous applications: the DATA ANALYSIS function is used to update the temperature, ventilation, power, temperature analysis, system status.
  • Page 13 Non-conformities must be reported within two months of having identified them. Devices or parts returned for replacement become the property of Thermorossi. The presence of irregular black-blue lines on the display (also present when de-energised and battery flat or missing) indicate that the glass screen of the display is damaged following a fall or impact: in this case the breakage is not covered by the guarantee.
  • Page 14 DESCRIPTION OF "ECOTHERM 3001 THERMOCOMFORT" CONTROLS DESCRIPTION OF "ECOTHERM 3001 THERMOCOMFORT" CONTROLS DESCRIPTION OF "ECOTHERM 3001 THERMOCOMFORT" CONTROLS DESCRIPTION OF "ECOTHERM 3001 THERMOCOMFORT" CONTROLS DESCRIPTION OF "ECOTHERM 3001 THERMOCOMFORT" CONTROLS 5A.1 5A.1 5A.1 DESCRIPTION OF CONTR DESCRIPTION OF CONTROL P...
  • Page 15 5A.2 D 5A.2 D 5A.2 D 5A.2 D 5A.2 DA A A A A Y Y Y Y Y AND AND TIME SETTING TIME SETTING TIME SETTING TIME SETTING TIME SETTING The heater must be fed with the rear switch in position "1". Display (7) may show the inscriptions On , OFF or Start. ". To set the time and the day of the week carry out the procedures described below.
  • Page 16 6 6 6 6 6 USE OF USE OF USE OF THE "ECO USE OF USE OF THE "ECO THE "ECO THE "ECO THE "ECOTHERM 3001" HEA THERM 3001" HEA THERM 3001" HEA THERM 3001" HEA THERM 3001" HEATER SWIT SWIT SWIT SWIT...
  • Page 17 (wash the filter with cold water then dry thoroughly every 5 days). USE OF USE OF USE OF THE "ECO USE OF USE OF THE "ECO THE "ECO THE "ECOTHERM 3001 THE "ECO THERM 3001 THERM 3001 THERM 3001 THERM 3001 THERMOCOMFOR THERMOCOMFOR THERMOCOMFOR THERMOCOMFORT" HEA THERMOCOMFOR T"...
  • Page 18 CAUTION: to guarantee optimal data transmission it is advisable to always place the radio control in its support in a vertical position. The following operations must be carried out the first time the heater is started up : - Turn the switch (11) to ON (see drawing below) - Connect the radio control by means of the battery charger supplied to the power line, ( it must be recharged for at least 5 days);...
  • Page 19 Non-conformities must be reported within two months of having identified them. Devices or parts returned for replacement become the property of Thermorossi. The presence of irregular black-blue lines on the display (also present when de-energised and battery flat or missing) indicate that the glass screen of the display is damaged following a fall or impact: in this case the breakage is not covered by the guarantee.
  • Page 20: Operating With The Additional Room Temperature Thermostat (Not Supplied )

    Contact 1-3 of the chronothermostat mod. "Perry". CAUTION: In the event of connections to the chronothermostat Thermorossi shall not be held responsible for the insert not starting up, smoke leaks, breakage of the lighting component. In the event of a programmed cycle on always ensure that the brazier is clean and seated correctly in its lodging.
  • Page 21: Cleaning And Maintenance

    Contact 1-3 of the chronothermostat mod. "Perry". CAUTION: In the event of connections to the chronothermostat Thermorossi shall not be held responsible for the insert not starting up, smoke leaks, breakage of the lighting component. In the event of a programmed cycle on always ensure that the brazier is clean and seated correctly in its lodging.
  • Page 22 THE HANDHELD RADIO CONTR THE HANDHELD RADIO CONTR THE HANDHELD RADIO CONTROL (standard ECOTHERM 3001, optional for ECOTHERM 3001 (standard ECOTHERM 3001, optional for ECOTHERM 3001 (standard ECOTHERM 3001, optional for ECOTHERM 3001 (standard ECOTHERM 3001, optional for ECOTHERM 3001...
  • Page 23 Turn the switch located in the battery compartment to 1, that is, OFF. The batteries are guaranteed for 6 months. Caution: Use only the battery charger provided by Thermorossi. The use of any other type of battery charger will invalidate the product warranty. REPLA...
  • Page 24: Smoke Outlet

    9.1.1 9.1.1 9.1.1 9.1.1 9.1.1 COMB COMB COMBUSTION COMB COMB USTION USTION USTION USTION AIR INT AIR INT AIR INT AIR INT AIR INTAKE The air required for combustion is taken directly from the room in which the heater is installed. The room where it is installed must always be adequately ventilated (1300 m3/h) .
  • Page 25 10 VOCAL ALARMS FOR ECOTHERM 3001 10 VOCAL ALARMS FOR ECOTHERM 3001 10 VOCAL ALARMS FOR ECOTHERM 3001 10 VOCAL ALARMS FOR ECOTHERM 3001 10 VOCAL ALARMS FOR ECOTHERM 3001 The heater is programmed to communicate 4 fundamental alarms. The vocal alarm is transmitted 4 times in rapid succession. It is transmitted in the following languages: Italian, English, German, French.
  • Page 26 ELECTRICAL WIRING DIAGRAM FOR ECOTHERM 3001 THERMOCOMFORT ELECTRICAL WIRING DIAGRAM FOR ECOTHERM 3001 THERMOCOMFORT ELECTRICAL WIRING DIAGRAM FOR ECOTHERM 3001 THERMOCOMFORT ELECTRICAL WIRING DIAGRAM FOR ECOTHERM 3001 THERMOCOMFORT ELECTRICAL WIRING DIAGRAM FOR ECOTHERM 3001 THERMOCOMFORT If another heater is installed in the vicinity of this heater T E R M O S T A T O 4 2°...
  • Page 27 INFORMA INFORMA INFORMATION FOR INFORMA INFORMA TION FOR TION FOR TION FOR TION FOR THE SKILLED THE SKILLED THE SKILLED THE SKILLED TECHNICIAN THE SKILLED TECHNICIAN TECHNICIAN TECHNICIAN TECHNICIAN 12.1 MAIN COMPONENTS AND THEIR OPERATION SMOKE PRESSURE SWITCH This is a safety switch that stops the screw feeder motor whenever necessary. The main cause for the pressure switch tripping is a blocked flue outlet or smoke exhaust pipe.
  • Page 28 12.3 TROUBLESHOOTING PROBLEM-CAUSE-SOLUTION (applies to ECOTHERM 3001) PR O BL EM CAU S E S O LU TI O N PELLET T ANK IS EM PT Y FILL UP TH E T ANK FOR EIGN BO DY SUC H A S NAIL, NYLO N, PIECE O F W OO D...
  • Page 29 12.4 TROUBLESHOOTING PROBLEM-CAUSE-SOLUTION (applies to ECOTHERM 3001 THERMOCOMFORT) P RO B LE M C A US E S O LU TI O N PE L LE T TA N K IS E MP TY (D ISP L AY S H O W S TH E IN SC RI P TI O N A L P E )
  • Page 30 LEGENDA K E Y Cuoio Leather Nera Black Beige Beige Rosso/a Easy Easy Inox Stainless steel (Sx con asole) (LH with slots) (Dx con asole) (RH with slots) Porta Completa Complete door Porta Ghisa Cast door Vetro Glass Guarnizioni Gaskets Maniglia acciaio Steel handle Semiguscio anteriore / posteriore...
  • Page 31 SPARE P ARE P ARE PAR ARTS 13.1 SPARE PARTS FOR "ECOTHERM 3001" AND "ECOTHERM 3001 THERMOCOMFORT" See key on page 35 6001 1 766 - C U O IO 7001 23 07 6001 1 767 - N E R A...
  • Page 32 13.2 SPARE PARTS FOR ALL "ECOTHERM 3001" AND "ECOTHERM 3001 THERMOCOMFORT" 7 0 0 0 4 5 3 7 P O R T A C O M P L E T A 7 0 0 1 2 2 7 7...
  • Page 33 7001 0402 7001 03 25 7001 023 4 6001 1 246 6001 01 90 7001 3 673 7001 3 3 06 ( E C O 3 001 fin o m atr. 1 042044067) 6001 3 1 3 9 ( E C O 3 001 d a m atr. 1 042044068) ( E C O 3 001 T h e rm o com fort) 7001 23 1 5 6001 01 49...
  • Page 34 13.4 SPARE PARTS FOR "ECOTHERM 3001" AND "ECOTHERM 3001 THERMOCOMFORT" See key on page 35 6001 2907 R O S S O (N .V .) 6001 1 764 R O S S A 6001 2909 C U O IO (N .V .) 6001 1 768 B E IG E 6001 2908 B E IG E (N .V .)
  • Page 35 6001 1 786 S U P P O R T O A M U R O A L A D IN O 6001 1 783 C O P E R C H IO P IL A R IC A R IC A B IL E 13.6 SPARE PARTS FOR "ECOTHERM 3001 THERMOCOMFORT" LEGENDA...

This manual is also suitable for:

Ecotherm 3001 thermocomfort