Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus INDEX 1 – INTRODUCTION..........................8 1.1 SAFETY GUIDELINES ............................. 8 1.2 SAFETY STANDARDS ............................. 8 1.3 RECOMMENDATIONS ............................. 8 1.4 GENERAL GUIDELINES ..........................8 1.5 TRANSPORTATION AND STORAGE ......................9 1.6 GUIDELINES FOR CORRECT DISPOSAL OF THE PRODUCT ..............
Page 4
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus 8.5 REPLACING THE BUFFER BATTERY OF THE CONTROL PANEL ............30 9 – SMOKE DISCHARGE TUBE AND VENTILATION OF THE ROOMS ..........31 9.1 FOREWORD ..............................31 9.2 ROOM VENTILATION ............................
Page 5
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus EU Declaration of Conformity (DoC) / Dichiarazione di Conformità UE (DoC) Company name: Postal address: THERMOROSSI S.P.A. VIA GRUMOLO, N° 4 Azienda: Indirizzo: Postcode and city:...
Page 6
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus La prestazione del prodotto di cui ai punti 1 e 2 è conforme alla prestazione dichiarata di cui al punto 8. Firma/Signature: Si rilascia la presente dichiarazione di prestazione sotto la responsabilità esclusiva del fabbricante di cui al punto 4.
Page 7
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus Rischio di fuoriuscita di braci incandescenti / Risk of burning fuel falling out Conforme/Compliant Temperatura superficiale/Surface temperature Conforme/Compliant Sicurezza elettrica / Electrical safety Conforme/Compliant Pulizia / Cleanability...
Page 8
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus IT – CLASSE DI EFFICIENZA ENERGETICA EN – ENERGY EFFICIENCY CLASS FR – CLASSE D'EFFICACITÉ ÉNERGÉTIQUE NL – ENERGIE EFFICIENTIEKLASSE DE – ENERGIEEFFIZIENZKLASSE ES – CLASE DE EFICIENCIA ENERGÉTICA IT –...
Thermorossi reserves the right to apply changes to the content of this manual anytime and without notice. Thermorossi S.p.A. retains copyright on this manual. These instructions may not be reproduced or communicated to third parties or used in any other way without the necessary authorisation.
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus ATTENTION: Before every use make sure that the burner and the ash pan are clean, and check that the sliding door is firmly closed and air tight.
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus 2 – TECHNICAL CHARACTERISTICS BELLAVISTA BELLAVISTA BELLAVISTA BELLAVISTA M.U. R2 SILENT R2 PLUS S2 SILENT S2 PLUS Height 1,493 1,493 1,489 1,489 667 – 975 667 –...
Page 12
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus ** It is important to take into consideration the fact that the heatable volume is greatly influenced by the insulation of the house (energy class of the building) and by the position of the appliance in the planimetry of the house, therefore the indicated values may vary, even significantly.
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus 3 – GENERAL DESCRIPTION 3.1 OPERATING TECHNOLOGY Your appliance has been built to fully satisfy all your heating and practical requirements. Top-grade components and functions managed with microprocessor technology guarantee high reliability and optimal performance.
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus 4 - INSTALLATION 4.1 APPLIANCE LOCATION Follow the general guidelines set out in paragraph 1.1 to the letter. Keep in mind that the flooring of the room in which the appliance is to be installed must withstand the combined weight of the appliance and the pellets contained in the tank.
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus 4.3 RELOCATION OF THE CONTROL PANEL The product is supplied with the control panel on the left side; if needed, the control panel can be moved to the right side of the appliance.
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus 4.4 INSTALLATION OF AIRBOX 3 VENTILATION KIT (OPTIONAL) Airbox 3 ventilation kit can be installed on the appliance. By introducing this optional, the appliance will become Plus, therefore ventilated and ductable.
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus C- dx C - sx 6) Insert deflectors (C – sx/LH) and (C – dx/RH). Open the 5) Unscrew the 4 knobs (A) and remove the cast-iron top (B), pulling it upward.
Il presente disegno è di proprietà esclusiva di THERMOROSSI S. p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito secondo i termini di legge in vigore.
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus 5 – DESCRIPTION OF THE CONTROLS The appliance, when operating, could be hot to the touch, particularly the glass of the combustion chamber: take care when handling the appliance components.
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus Display The following information can appear on the display: SILENT version PLUS version Displays the preset combustion power, and consequently the pellet consumption, by the number of bars that are...
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus 2) After a few seconds the following screen will appear on the display: 3) Now press the Scroll Buttons to change the day of the week; each number corresponds to one day of the week (e.g. 1 corresponds to Monday, 2 corresponds to Tuesday, etc...).
Page 22
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus 5-B) Press the Scroll Buttons to select the hour at which you wish the appliance to start up automatically for the second time (ON2). The start up time will be that set before OFF1; this is to avoid setting a second start up time that is earlier than the preceeding shut off time.
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus Enabling the programmed cycles: Back in the initial screen, to enable the appliance to carry out the ON/OFF cycles as programmed it is necessary to press the Clock Button.
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus 5.6 ROOM CONTROL: CONNECTION WITH THE ROOM CONTROL DEVICE (OPTIONAL) See the specific manual for the ROOM CONTROL device (Optional). Page 23...
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus 6 – USE OF THE APPLIANCE 6.1 DESCRIPTION OF THE OPERATING STAGES START: has a duration of approx. 20 minutes, during this phase the appliance is programmed to light the flame. The appliance will not accept power variations in the firebox.
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus 6.5 CHANNELLING It is possible to choose to distribute the flow partly to the front and partly to the channelling at the rear (only in the PLUS version).
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus 7 – ROOM TEMPERATURE THERMOSTAT / CHRONOTHERMOSTAT (optional) The appliance can be connected to an additional room temperature thermostat or to an additional chronothermostat: This operation must be exclusively performed by qualified professional staff, as set forth by Decree no. 37 of 22nd January 2008 and applicable laws on the subject.
Page 28
ATTENTION: Use N.O. (normally open) contacts for the connection to the chronothermostat. ATTENTION: In the event of connections to the chronothermostat Thermorossi S.p.a. shall not be held responsible for the appliance not starting up, smoke leaks or breakage of the lighting component. In the event of a programmed cycle on always ensure that the brazier is clean and seated correctly in its lodging.
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus 8 - CLEANING AND MAINTENANCE 8.1 FOREWORD Before beginning any maintenance operation ensure that the appliance is switched OFF and disconnected from the electric power socket. Your appliance, being a pellet-fuelled appliance, requires regular general controls and cleaning.
Page 30
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus ATTENTION: the generator, the smoke channel and flue outlet must be cleaned in accordance with the specifications described above and use of inflammable products is strictly forbidden: using inflammable products can create dangerous situations.
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus FIGURE - 8 FIGURE - 7 8.3 AIR FILTER Your appliance is fitted with an air filter (only in the PLUS version); a practical device that prevents the circulation of dust particles that are always present in domestic environments.
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus 9 – SMOKE DISCHARGE TUBE AND VENTILATION OF THE ROOMS 9.1 FOREWORD Due to the frequent accidents caused by poor functioning of flue outlets installed in private dwellings, we have prepared the following paragraph to assist the installer in his inspection of the parts concerned with eliminating the gases produced by combustion.
Page 33
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus Page 32...
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus 9.3.2 FLUE OUTLET / FLUE SYSTEM COMPONENTS Components and accessories of a chimney Every chimney must have minimum number of components as laid down 1 Chimney by standard UNI EN 1443 which are also indicated in the figure on the left.
ATTENTION: The appearance of one of the alarms described below, does not necessarily imply a defect in the product, but simply Thermorossi S.p.A.’s intention to inform the user of the need for corrective actions in order to guarantee maximum safety, greater reliability and high performance of the appliance.
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus 12 – INFORMATION FOR THE SKILLED TECHNICIAN 12.1 MAIN COMPONENTS AND THEIR OPERATION SMOKE PRESSURE SWITCH This is a safety switch that stops the screw feeder motor whenever necessary. The main cause for the pressure switch tripping is a blocked flue outlet or smoke exhaust pipe.
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus 12.3 TROUBLESHOOTING CAUSE-SOLUTION PROBLEM POSSIBLE CAUSE SOLUTION CLEAN THE BRAZIER AS INDICATED IN THIS USE AND PELLET TANK IS EMPTY MAINTENANCE GUIDE, THEN FILL UP THE TANK WITH THE FOLLOWING ALARM IS SHOWN ON THE DISPLAY “NO PELLET”...
Page 39
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus ROOM TEMPERATURE THERMOSTAT SET TOO LOW, APPLIANCE OPERATES THE APPLIANCE NEEDS TO RUN FOR MORE HOURS AT A INTERMITTENTLY HIGHER POWER; SET A HIGHER ROOM TEMPERATURE...
Page 40
Installation, use and maintenance guide BellaVista R2 Silent – Plus, BellaVista S2 Silent – Plus Page 39...