Download Print this page
THERMOROSSI PIDRA 18 EVO Installation, Use And Maintenance Manual
THERMOROSSI PIDRA 18 EVO Installation, Use And Maintenance Manual

THERMOROSSI PIDRA 18 EVO Installation, Use And Maintenance Manual

Advertisement

Quick Links

PIDRA 18 EVO
ITA - MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE.
FRA - MANUEL D'INSTALLATION, D'UTILISATION ET ENTRETIEN.
ENG - INSTALLATION, USE AND MAINTENANCE GUIDE.
DEU - INSTALLATIONS, BETRIEBS UND WARTUNGSANLEITUNG.
ESP - MANUAL DE INSTALACIÓN USO Y MANTENIMIENTO.
NL - HANDLEIDING VOOR INSTALLATIE, GEBRUIK EN ONDERHOUD.
ITA – Informazioni importanti per la sicurezza ed il corretto funzionamento.
FRA – A lire impérativement ! Informations importantes pour la sécurité et le bon fonctionnement.
ENG – Must read! Important information for safety and correct operation.
DEU – Unbedingt lesen! Wichtige informationen zur sicherheit und zum sicheren betrieb.
ESP – ¡Leer! Informaciones importantes para la seguridad y el correcto funcionamiento.
NL – Belangrijke informatie voor de veiligheid en correcte werking.

Advertisement

loading
Need help?

Need help?

Do you have a question about the PIDRA 18 EVO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for THERMOROSSI PIDRA 18 EVO

  • Page 1 PIDRA 18 EVO ITA - MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE. FRA - MANUEL D’INSTALLATION, D’UTILISATION ET ENTRETIEN. ENG - INSTALLATION, USE AND MAINTENANCE GUIDE. DEU - INSTALLATIONS, BETRIEBS UND WARTUNGSANLEITUNG. ESP - MANUAL DE INSTALACIÓN USO Y MANTENIMIENTO. NL - HANDLEIDING VOOR INSTALLATIE, GEBRUIK EN ONDERHOUD.
  • Page 2 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) Page 2...
  • Page 3 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) INDEX 1 – INTRODUCTION ..........................5 2 – TECHNICAL CHARACTERISTICS ...................... 7 3 – GENERAL DESCRIPTION ........................8 4 – INSTALLATION ........................... 9 5 – HYDRAULIC CONNECTION ......................12 6 –...
  • Page 4 DECLARATION OF PERFORMANCE ACCORDING TO REGULATION (EU) 305/2011 Codice di identificazione unico del prodotto-tipo: PIDRA 18 EVO Modello, lotto, serie ai sensi dell'articolo 11, paragrafo 4: PIDRA 18 EVO Unique identification code of the product type: Model, batch or serial number required under Article 11 (4):...
  • Page 5 If the appliance is sold or transferred to another user ensure that the manual is handed over with it. Thermorossi S.p.A. retains copyright on this manual. These instructions may not be reproduced or communicated to third parties or used in any other way without the necessary authorisation.
  • Page 6 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) 1.4 GENERAL WARNINGS Attention: the appliance must be connected to a system provided with a PE conductor (in compliance with the specifications of 2006/95/EC, concerning low voltage equipment). Before installing the appliance, check the efficiency of the earth circuit of the power supply system.
  • Page 7 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) 2 – TECHNICAL CHARACTERISTICS PIDRA 14 M.U. VALUES Empty weight Firebox power Min. / Max.* 5.3 / 18.9 Rated power Min. / Max.* 5.1 / 17.8 Output to water Min.
  • Page 8 è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito secondo i termini di legge in vigore. Take special care when loading the tank as the screw feeder at its base...
  • Page 9 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) Should you notice an excessive stagnation of flue gas in the combustion chamber, move away from the appliance immediately. In particular move away from the glass door of the combustion chamber. The excessive concentration of unburned gases could create an explosion that could break the glass.
  • Page 10 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) 4 – INSTALLATION 4.1 APPLIANCE LOCATION Follow the general guidelines set out in paragraph 1.1 to the letter. Above all keep in mind that the flooring of the room in which the stove is being installed must withstand the weight of the stove with the added weight of the pellet load and the water contained in it.
  • Page 11 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) 4.3 UNPACKING/MOUNTING THE CASING See the specific manual for the casing. 4.4 CONNECTION TO THE FLUE OUTLET 47.4 Connection of the appliance to the flue outlet must be...
  • Page 12 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) 5 – HYDRAULIC CONNECTION 5.1 GENERATOR PLUMBING COMPONENTS DETAIL A DETTAGLIO A System circulating pump 2 l closed expansion tank Automatic relief valve Plant delivery Boiler water temperature sensor...
  • Page 13 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) 5.2 GUIDELINES FOR PLANTS WITH ZONE VALVES Note: above 61°C, the generator pump is always active as it is essential to dissipate the heat; therefore, the solenoid valve must be open for the following reasons: •...
  • Page 14 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) 5.3 HYDRAULIC DIAGRAM WITH HEATING ONLY VM3VT Heating plant delivery VM3VT Mixing valve set at 55°C andata impianto riscaldamento Heating plant return Gate valve to throttle the flow...
  • Page 15 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) ATTENTION: the water temperature in the boiler tubes in this case is not adjustable and depends on the system's delivery temperature, that is the temperature set in the generator. The boiler tubes can be installed on the water return circuit. It is recommended to install a water softener in the domestic water system in order to maintain the boiler at its peak efficiency.
  • Page 16 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) 5.6 HYDRAULIC DIAGRAM WITH THERMOCELL + THERMOPUFFER + HEATING Attenzione : chiudere tutti i fori Attenzione : chiudere tutti i fori Riscaldamento pavimento non usati del puffer...
  • Page 17 The nominal volume of the additional closed expansion tank must be sized in relation to the volume of expansion of the water contained in the system. Thermorossi prescribes that the size of the additional closed expansion tank must be equal to 10% of the water contained in the system.
  • Page 18 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) Flame button Pressing this button when the appliance is off activates the START sequence (see dedicated paragraph), sets the operating power in the WORK mode (see dedicated paragraph) or shuts off the appliance by activating the OFF sequence (see dedicated paragraph).
  • Page 19 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) Indicates the temperature of the domestic hot water boiler, if the optional sensor is connected. Indicates the temperature of Sensor S1 for control of a puffer, if the optional sensor is connected.
  • Page 20 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) 6.4 CHRONO: ON/OFF PROGRAMMING The appliance must be energised and the I/0 switch in position “I". The CHRONO function allows you to set the weekly program by setting up to 3 on-off cycles at different times for every day from Monday through to Sunday.
  • Page 21 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) 6-B) Press the Scroll Buttons to select the hour at which you wish the appliance to start up automatically for the third time (ON3). The start up time will be that set before OFF2; this is to avoid setting a third start up time that is earlier than the preceding shut off time.
  • Page 22 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) Resetting the programmed cycles: Moreover, it is possible to reset, in other words delete, all the programmed cycles entered by the user by holding down the Clock Button in the initial screen for approx.
  • Page 23 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) 6.6 THERMOCONTROL: CONTROLLING A PUFFER The appliance must be energised and the I/0 switch in position “I". This function enables you to control the operating temperature of a stratification puffer through the use of two sensors PT 100 (optional) connected to the respective terminal blocks on the electronic board (see dedicated paragraph).
  • Page 24 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) By setting THERMOCONTROL ON, when the puffer is requesting heat, the temperatures detected by the sensors S1 and S2 and the word PUF will appear on the display.
  • Page 25 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) ATTENTION: if an external chrono-thermostat is connected to the appliance, it is not necessary to program any operating time band as the appliance will follow the cycles set in the external chrono-thermostat. Consequently, simply press the Menu Button several times to exit the screen, until the initial screen appears.
  • Page 26 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) Press one of the two Scroll Buttons and the following screen will appear (Select ON to activate): Press the Menu Button several times, to confirm and exit the screen, until the initial screen appears.
  • Page 27 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) After a few seconds the following screen will appear on the display: Press one of the two Scroll Buttons and the following screen will appear (Select ON to activate): Confirm the selection by pressing the Degrees Button and the following screen will appear: Press the Scroll Buttons to set the minimum activation temperature for the sensor.
  • Page 28 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) When is it important to use the THERMO ACS function together with the THERMOCONTROL function? In systems configured like the nearby diagram, where the appliance is installed in a system fitted with both a boiler and a puffer.
  • Page 29 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) SUN OUT: this function only activates automatically if the THERMOCONTROL function is turned to ON and if solar panels are connected to the puffer. When Sensor S2 detects a temperature over 80°C and the appliance is in OFF mode, the text SUNOUT will appear on the display accompanied by the circulating pump active indicator and activation of the smoke suction unit at the maximum power.
  • Page 30 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) 6.10.4 MANUAL OPERATING CYCLE The manual cycle is indicated on the display by the power bars. The power expressed in this cycle remains always constant independently from the power absorbed by the system. As always, the system's circulating pump is activated at the anticondensation temperature, that is above 61°C.
  • Page 31 230 V or lower voltages, as this would seriously damage the control board, and is not covered by warranty. ATTENTION: in the event of connections to the chrono-thermostat, Thermorossi shall not be held responsible for the appliance not starting up, smoke leaks, breakage of the lighting component.
  • Page 32 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) Legenda Cronotermostato Modem Chrono-thermostat - Modem Contatti 9-10 della morsettiera CN7 Contacts 9-10 of the terminal block CN7 Termostato Ambiente Room Temperature Thermostat Contatti 7-8 della morsettiera CN7...
  • Page 33 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) EVERY MONTH: •Inspect and clean the Tee-joint of the smoke exhaust pipe. •Vacuum, when empty, the saw dust on the bottom of the pellet tank. •Check that the smoke exhaust pipe is free from any ash deposits, above all in the initial parts that could have a smaller section.
  • Page 34 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) FIGURE 2 FIGURE 3 Page 34...
  • Page 35 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) FIGURE 4 FIGURE 5 DETAIL D Page 35...
  • Page 36 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) FIGURE 6 DETAIL B Page 36...
  • Page 37 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) FIGURE 7 Page 37...
  • Page 38 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) 9 – SMOKE DISCHARGE TUBE AND VENTILATION OF THE ROOMS 9.1 FOREWORD Due to the frequent accidents caused by poor functioning of flue outlets installed in private dwellings, we have prepared the following paragraph to assist the installer in his inspection of the parts concerned with eliminating the gases produced by combustion.
  • Page 39 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) 9.3 SMOKE OUTLET The smoke channel, the exhaust pipe, chimney and flue outlet (defined as the system for the Components and accessories of a chimney evacuation of combustion products), are parts of...
  • Page 40 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) LEGENDA COMIGNOLO E CANNA FUMARIA SECONDO NORMA UNI 10683 CHIMNEY CAP AND FLUE OUTLET ACCORDING TO UNI 10683 STANDARD TUTTE LE TUBAZIONI DEVONO ESSERE TERMICAMENTE ISOLATE...
  • Page 41 ATTENTION: the appearance of one of the alarms described below, does not necessarily imply a defect in the product, but simply Thermorossi S.p.A.’s intention to inform the user of the need for corrective actions in order to guarantee maximum safety, greater reliability and high performance of the appliance.
  • Page 42 To access the electronic board, it is necessary to follow the instructions indicated in the above drawings: Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito secondo i termini di legge in vigore.
  • Page 43 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) LEGENDA Sensore Hall aspiratore fumi Hall Sensor smoke suction unit Pannello comandi Control panel Termocoppia fumi Smoke thermocouple Sonda PT 100 (ACS) optional Sensor PT 100 (ACS) optional...
  • Page 44 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) 12 – INFORMATION FOR THE SKILLED TECHNICIAN 12.1 MAIN COMPONENTS AND THEIR POSITION SMOKE PRESSURE SWITCH This is a safety switch that stops the screw feeder motor whenever necessary. The main cause for the pressure switch tripping is a blocked flue outlet or smoke exhaust pipe.
  • Page 45 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) 12.2 GUIDELINES FOR CORRECT INSTALLATION • Read this instruction booklet. • The appliance must always be switched off from the control panel. It is forbidden to switch off the appliance by means of the main switch 0/I.
  • Page 46 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) 12.3 TROUBLESHOOTING CAUSE / SOLUTION PROBLEM CAUSE SOLUTION CLEAN THE BRAZIER AS INDICATED IN THIS USE AND PELLET TANK IS EMPTY MAINTENANCE GUIDE, THEN FILL UP THE TANK WITH THE ALARM “NO PELLET-CLEAN BURNER”...
  • Page 47 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) THE SPARK PLUG IS NOT WORKING CLEAN THE BRAZIER AS INDICATED IN THIS USE AND THE ALARM “FAILED START-CLEAN BURNER” IS DISPLAYED. MAINTENANCE GUIDE, THEN REPLACE THE SPARK PLUG...
  • Page 48 Manuale d'installazione, uso e manutenzione Stove body Idra Pellet 18 kW (PIDRA 18 EVO) NOTES Fire Lovers Via Grumolo, 4 (Z.I.) 36011 Arsiero (VI) - ITALY Fax 0445.741657 - www.thermorossi.com - info@thermorossi.it Page 48...