Installation, use and maintenance guide Pellet Air 11 Stove body INDEX 1 - INTRODUCTION ..........................7 1.1 GENERAL GUIDELINES ..........................7 1.2 SAFETY GUIDELINES ............................. 7 1.3 RECOMMENDATIONS ............................. 7 1.4 GENERAL GUIDELINES ..........................8 1.5 TRANSPORTATION AND STORAGE ......................8 TECHNICAL CHARACTERISTICS* ....................
Page 3
14.3 SPARE PARTS FOR PELLET AIR 11 STOVE BODY (PAIR 11) PAGE 3/3 ..........45 14.4 SPARE PARTS FOR PELLET AIR 11 PLUS STOVE BODY (PAIRPLUS 11) PAGE 1/3 ......46 14.5 SPARE PARTS FOR PELLET AIR 11 PLUS STOVE BODY (PAIRPLUS 11) PAGE 2/3 ......47 14.6 SPARE PARTS FOR PELLET AIR 11 PLUS STOVE BODY (PAIRPLUS 11) PAGE 3/3 ......
Page 4
Installation, use and maintenance guide Pellet Air 11 Stove body DECLARATION OF CONFORMITY La THERMOROSSI S.P.A., VIA GRUMOLO N° 4 36011 ARSIERO (VI), sotto la sua esclusiva responsabilità DICHIARA DECLARES that the product: Descrizione Stufa a pellet Description Pellet stove Marchio THERMOROSSI S.P.A.
Page 5
Codice di identificazione unico del prodotto-tipo: Unique identification code of the product type: PELLET AIR 11, apparecchio per il riscaldamento domestico, senza acqua, alimentato a pellet di legno PELLET AIR 11, residential space heating appliance without water fired by wood pellets...
Page 6
Installation, use and maintenance guide Pellet Air 11 Stove body Prestazione dichiarata / Declared performance Specifica tecnica armonizzata: EN 14785:2006 Harmonized technical specification: Caratteristiche Essenziali Prestazione / Performance Essential characteristics Sicurezza antincendio / Fire safety Reazione al fuoco / Reaction to fire...
If this manual is lost and/or damaged it is mandatory to ask the manufacturer for a replacement copy. Thermorossi S.p.A. retains copyright on theses service instructions. These instructions may not be reproduced or communicated to third parties or used in any other way without the necessary authorisation.
Installation, use and maintenance guide Pellet Air 11 Stove body 1.4 GENERAL GUIDELINES Caution: the appliance must be connected to a system provided with a PE conductor (in compliance with the specifications of 73/23/EEC, 93/98/EEC, concerning low voltage equipment). Before installing the appliance check the efficiency of the earth circuit of the power supply system.
Installation, use and maintenance guide Pellet Air 11 Stove body TECHNICAL CHARACTERISTICS* PELLET AIR 11 PELLET AIR 11 NOT DUCTABLE DUCTABLE (PLUS) Height (mm) 1114 1114 Depth (mm) Width (mm) Empty weight without casing (Kg) Firebox power Min. / Max. (KW) 4.80 / 13.18...
Pellet Air 11 Stove body O 50 PAIR 11 PELLET AIR 11 STOVE BODY PAIR11 - CORPO STUFA PELLET AIR 11 GENERAL DESCRIPTION 3.1 OPERATING TECHNOLOGY Your appliance has been built to fully satisfy all your heating and practical requirements. Top-grade components and functions managed with microprocessor technology guarantee high reliability and optimal performance.
Installation, use and maintenance guide Pellet Air 11 Stove body 4 - INSTALLATION 4.1 APPLIANCE LOCATION Follow the general guidelines set out in paragraph 1.1 to the letter. Keep in mind that the flooring of the room in which the appliance is to be installed must withstand the total weight of the appliance combined with the pellets contained in the tank.
Installation, use and maintenance guide Pellet Air 11 Stove body 4.2 UNPACKING THE APPLIANCE To unpack the appliance remove the packaging cover and sides, undo the 4 screws C that fix the appliance to the pallet. To remove the 2 screws C indicated in Figure 1 firstly remove the bracket A by undoing the screws B. Next undo the last 2 screws C as illustrated in Figure 2.
Installation, use and maintenance guide Pellet Air 11 Stove body 4.10 CONNECTING THE APPLIANCE TO THE FLUE OUTLET Connection of the appliance to the flue outlet must be carried out in strict compliance with the instructions contained in this use and maintenance guide.
Page 14
Installation, use and maintenance guide Pellet Air 11 Stove body If there is not sufficient depth the size can be reduced to roughly 80 mm; follow the images 4, 5, 6, 7. In particular: -Remove the tank cover (Figure 4).
Installation, use and maintenance guide Pellet Air 11 Stove body 4.11 HANDLE Your appliance is supplied with a handle for opening the firebox door; this tool must be used for opening the door to permit carrying out cleaning operations (see paragraph 8). The handle, when not being used, can be stored at the back of the appliance on the hook provided (see Figures 1 and 2).
Page 16
Installation, use and maintenance guide Pellet Air 11 Stove body The control panel is managed by a microprocessor. The control buttons and the various displays are described below. The control buttons are: Clock button Press this button to activate / deactivate the programming. (See para. 5.4), Ventilation button Press this button to set the desired level of ventilation: Six ventilation levels can be set on this stove.
Installation, use and maintenance guide Pellet Air 11 Stove body 5.2 DESCRIPTION OF THE POWER PANEL The components of the power panel are described below: 1) Electrical power outlet 220V-240V 50Hz 2) Main switch 0/I. 3) Test light for pellet feed motor.
Page 18
Installation, use and maintenance guide Pellet Air 11 Stove body After a few seconds the following screen will appear on the display: 2) Press the Scroll Buttons to select the day of the week on which you want to set the program. Each dot corresponds to one day of the week (e.g.
Page 19
Installation, use and maintenance guide Pellet Air 11 Stove body 6-A) Press the Menu Button to exit the screen, in order to enable you to program the times for the ON/OFF cycles for the other days of the week. In this case repeat the instructions from point 2 up to this paragraph.
Installation, use and maintenance guide Pellet Air 11 Stove body The text CR.OFF will appear on the display and the clock symbol will disappear. This operation disables the weekly program th at has been set by the user but does not delete or reset the times.
Installation, use and maintenance guide Pellet Air 11 Stove body After a few seconds the following screen will appear on the display: Press the left Scroll Button and the following screen will appear (Select ON to activate). ATTENTION: It will only be possible to activate the THERMOCOMFORT function and select ON in the previous screen if the appliance detects the radio control signal.
Installation, use and maintenance guide Pellet Air 11 Stove body 6 - OPERATION OF THE HANDHELD RADIO CONTROL THERMOCOMFORT (OPTIONAL) The Thermocomfort handheld radio control is the instrument that allows you to optimise both consumption and functions. If set in AUTO mode, the radio control detects the room temperature where it is located and automatically manages the modulation of the combustion power and the ventilation power of the appliance according to the target temperature set by the user in the radio control.
Installation, use and maintenance guide Pellet Air 11 Stove body Remove the battery cover and flick the main switch to ON, as illustrated in the figure below. (This operation is only required the first time you switch on the radio control) Flick the main switch upwards (11): Connect the radio control to the mains power supply by means of the supplied battery charger.
Installation, use and maintenance guide Pellet Air 11 Stove body To set or change the combustion power simply press the Flame Button (1), and the flame symbol on the screen will begin to flash for several seconds. While it is flashing press the Down arrow (3) to reduce the combustion power, and on the display you will see the bars disappear in sequence;...
Devices or parts returned for replacement become the property of Thermorossi. S.p.A. The presence of any irregular black-blue lines on the display, also present when de-energised and/or battery flat or missing, indicate that the glass screen of the display is damaged following a fall or impact: in this case the breakage is not covered by the guarantee.
Installation, use and maintenance guide Pellet Air 11 Stove body USE OF THE APPLIANCE 7.1 DESCRIPTION OF THE OPERTATING STAGES START: has a duration of approx. 20 minutes, during this phase the appliance is programmed to light the flame. The appliance will not accept power variations in the firebox.
Installation, use and maintenance guide Pellet Air 11 Stove body 7.5 FILTER This practical device prevents the circulation of dust which is always present in household environments. The filter (marked by letter A in the figure on the side) is installed at the back of the appliance (see figure 1 on the side).
Installation, use and maintenance guide Pellet Air 11 Stove body 8 - ADDITIONAL ROOM TEMPERATURE THERMOSTAT (not supplied) ADDITIONAL CHRONOTHERMOSTAT - MODEM (not supplied) The appliance can be connected to an additional room temperature thermostat or to an additional chronothermostat: --->...
ATTENTION: Use N.O. (normally open) contacts for the connection to the chronothermostat. ATTENTION: In the event of connections to the chronothermostat Thermorossi S.p.a. shall not be held responsible for the insert not starting up, smoke leaks or breakage of the lighting component. In the event of a programmed cycle on always ensure that the brazier is clean and seated correctly in its lodging.
Page 30
Installation, use and maintenance guide Pellet Air 11 Stove body EVERY MONTH check that the smoke exhaust is free from fly ash deposits, particularly in the initial sections. EVERY MONTH vacuum the ash deposited on the bottom of the tank (when the tank is empty).
Page 31
Installation, use and maintenance guide Pellet Air 11 Stove body Figura 2 B Figura 4A Page 31...
Page 32
Installation, use and maintenance guide Pellet Air 11 Stove body Figura 4 B Figura 4 C Page 32...
Page 33
Installation, use and maintenance guide Pellet Air 11 Stove body Figura 5 Figura 6 Page 33...
The batteries are guaranteed for 6 months. Attention: Use only the battery charger provided by Thermorossi S.p.a. The use of any other type of battery charger will invalidate the product warranty. Flat batteries must be removed and safely disposed of. Use rechargeable AAA 1.2 V min.
Installation, use and maintenance guide Pellet Air 11 Stove body SMOKE DISCHARGE TUBE AND VENTILATION OF THE ROOMS 10.1 FOREWORD Due to the frequent accidents caused by poor functioning of flue outlets installed in private dwellings, we have prepared the following paragraph to assist the installer in his inspection of the parts concerned with eliminating the gases produced by combustion.
Installation, use and maintenance guide Pellet Air 11 Stove body 10.3.2 FLUE OUTLET / FLUE SYSTEM COMPONENTS Components and accessories of a chimney Keys Every chimney must have minimum number of components as laid down by 1 Chimney standard UNI EN 10683 which are also 2 Flow path indicated in the figure on the left.
Installation, use and maintenance guide Pellet Air 11 Stove body 10.3.3 CONTROLS PRIOR TO INSTALLING THE APPLIANCE The user must possess a certificate of conformance for the flue outlet (Ministerial Decree 22 January 2008, no. 37). The flue outlet must be built in compliance with UNI 10683.
Installation, use and maintenance guide Pellet Air 11 Stove body ALARMS The appliance is programmed to communicate 7 fundamental alarms. The alarms are listed below: ALPE Appears when the temperature during the WORK mode drops below the fixed threshold: this indicates that the appliance is switching off or switched off due to lack of pellets.
Installation, use and maintenance guide Pellet Air 11 Stove body 13 - INFORMATION FOR THE SKILLED TECHNICIAN 13.1 MAIN COMPONENTS AND THEIR OPERATION SMOKE PRESSURE SWITCH This is a safety switch that stops the screw feeder motor whenever necessary. The main cause for the pressure switch tripping is a blocked flue outlet or smoke exhaust pipe.
Installation, use and maintenance guide Pellet Air 11 Stove body 13.3 TROUBLESHOOTING CAUSES-SOLUTION PROBLEM POSSIBLE CAUSE SOLUTION PELLET TANK IS EMPTY CLEAN THE BRAZIER AS INDICATED IN THIS USE AND ALARM IS SHOWN ON THE DISPLAY MAINTENANCE GUIDE, THEN FILL UP THE TANK WITH PELLETS...
Installation, use and maintenance guide Pellet Air 11 Stove body PROBLEM POSSIBLE CAUSE SOLUTION ROOM TEMPERATURE THERMOSTAT SET TOO LOW, APPLIANCE OPERATES THE APPLIANCE NEEDS TO RUN FOR MORE HOURS AT A INTERMITTENTLY HIGHER POWER; SET A HIGHER ROOM TEMPERATURE...