THERMOROSSI URBAN Installation, Use And Maintenance Manual

THERMOROSSI URBAN Installation, Use And Maintenance Manual

Advertisement

Quick Links

Installation, use and maintenance guide
Models:
- URBAN
- URBAN E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the URBAN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for THERMOROSSI URBAN

  • Page 1 Installation, use and maintenance guide Models: - URBAN - URBAN E...
  • Page 2 Installation, use and maintenance guide Urban – Urban E Page 1...
  • Page 3: Table Of Contents

    Installation, use and maintenance guide Urban – Urban E INDEX 1 – INTRODUCTION..........................6 1.1 SAFETY GUIDELINES ............................. 6 1.2 SAFETY STANDARDS ............................. 6 1.3 RECOMMENDATIONS ............................. 6 1.4 GENERAL GUIDELINES ..........................6 1.5 TRANSPORTATION AND STORAGE ......................7 1.6 GUIDELINES FOR CORRECT DISPOSAL OF THE PRODUCT ..............7 2 –...
  • Page 4 Installation, use and maintenance guide Urban – Urban E 11 – ELECTRONIC BOARD ........................27 12 – INFORMATION FOR THE SKILLED TECHNICIAN ................. 28 12.1 MAIN COMPONENTS AND THEIR POSITION ................... 28 12.2 PRESCRIPTIONS FOR CORRECT USE ..................... 28 12.3 TROUBLESHOOTING CAUSE-SOLUTION ....................29...
  • Page 5 DECLARATION OF PERFORMANCE ACCORDING TO REGULATION (EU) 305/2011 Codice di identificazione unico del prodotto-tipo: URBAN Modello, lotto, serie ai sensi dell'articolo 11, paragrafo 4: URBAN Unique identification code of the product type: Model, batch or serial number required under Article 11(4):...
  • Page 6 DECLARATION OF PERFORMANCE ACCORDING TO REGULATION (EU) 305/2011 Codice di identificazione unico del prodotto-tipo: URBAN E Modello, lotto, serie ai sensi dell'articolo 11, paragrafo 4: URBAN E Unique identification code of the product type: Model, batch or serial number required under Article 11(4):...
  • Page 7: Introduction

    Thermorossi reserves the right to apply changes to the content of this manual anytime and without notice. Thermorossi S.p.A. retains copyright on this manual. These instructions may not be reproduced or communicated to third parties or used in any other way without the necessary authorisation.
  • Page 8: Transportation And Storage

    At the end of the product’s useful life it must be disposed of in compliance with applicable regulations and in respect of the environment, not with urban waste. The product must be consigned to designated sorted waste collection centres for the disposal of electronic waste authorised by the local municipal councils. Correct disposal not only helps safeguard the environment but it also promotes recovery and recycling of the materials.
  • Page 9: Technical Characteristics

    Installation, use and maintenance guide Urban – Urban E 2 – TECHNICAL CHARACTERISTICS URBAN M.U. URBAN E Height Depth Width 439.1 Empty weight 95.1 82.7 Firebox power (Min. / Max.)* 4.00 / 8.00 Rated power Min. / Max.* 3.70 / 7.10 Consumption (Min.
  • Page 10: General Description

    Installation, use and maintenance guide Urban – Urban E 3 – GENERAL DESCRIPTION 3.1 OPERATING TECHNOLOGY Your appliance has been built to fully satisfy all your heating and practical requirements. Top-grade components and functions managed with microprocessor technology guarantee high reliability and optimal performance.
  • Page 11: Installation

    Installation, use and maintenance guide Urban – Urban E 4 - INSTALLATION 4.1 APPLIANCE LOCATION Follow the general guidelines set out in paragraph 1.1 to the letter. Keep in mind that the flooring of the room in which the appliance is to be installed must withstand the total weight of the appliance combined with the pellets contained in the tank.
  • Page 12: Description Of The Controls

    Installation, use and maintenance guide Urban – Urban E 5 – DESCRIPTION OF THE CONTROLS The appliance, when operating, could be hot to the touch, particularly the door of the combustion chamber: take care when handling the appliance components. Your appliance has obtained the CE marking and has been made to run for at least one hour to check that it functions correctly.
  • Page 13: Description Of The Power Panel

    Installation, use and maintenance guide Urban – Urban E Displays the preset combustion power, and consequently the pellet consumption, by the number of bars that are lit up around the flame symbol, using this logic: One bar lit: Minimum combustion power (and therefore with minimum pellet consumption).
  • Page 14: Date/Time: Setting The Date And Time

    Installation, use and maintenance guide Urban – Urban E 5) Electrical power outlet 220V-240V 50Hz 6) Protection fuse 3.15 A. 5.3 DATE/TIME: SETTING THE DATE AND TIME The appliance must be energised and the I/0 switch in position “I". The current date and time can be set using the DATE/TIME function.
  • Page 15 Installation, use and maintenance guide Urban – Urban E Once confirmed, the selector shifts to the minute section of OFF1. Press the Scroll Buttons to set the minutes for the first shut off. Confirm the value by pressing the Flame Button.
  • Page 16: Level: Operating Level Setting

    Installation, use and maintenance guide Urban – Urban E 7) To conclude the programming operations simply press the Menu Button several times to exit the box until the initial screen will appear. ATTENTION: The appliance ignores any ON or OFF command programmed with a value of 00:00. Consequently if you do not wish to use an ON or OFF time setting simply set a value of 00:00.
  • Page 17: Room Control: Connection With The Room Control Device (Optional)

    Installation, use and maintenance guide Urban – Urban E Select the required Level by acting as follows: Press the Menu Button three times quickly and the following box will appear: After a few seconds the following screen will appear on the display: To change the operating level, hold down a Scroll Button while simultaneously pressing the other Scroll Button.
  • Page 18: Use Of The Appliance

    Installation, use and maintenance guide Urban – Urban E 6 – USE OF THE APPLIANCE 6.1 DESCRIPTION OF THE OPERATING STAGES START: has a duration of approx. 20 minutes, during this phase the appliance is programmed to light the flame. The appliance will not accept power variations in the firebox.
  • Page 19: Chronothermostat (Optional)

    Chrono function on the panel. In the event of connections to the chronothermostat Thermorossi shall not be held responsible for the appliance not starting up, smoke leaks, breakage of the lighting component.
  • Page 20: Cleaning And Maintenance

    Installation, use and maintenance guide Urban – Urban E 8 - CLEANING AND MAINTENANCE 8.1 FOREWORD Before beginning any maintenance operation ensure that the appliance is switched OFF and disconnected from the electric power socket. Your appliance, being a pellet-fuelled appliance, requires regular general controls and cleaning.
  • Page 21 Installation, use and maintenance guide Urban – Urban E ATTENTION: if the appliance remains inactive and/or unused for more than one month, it is necessary to clean the entire appliance thoroughly, as well as the smoke discharge tube and the flue outlet, to remove any obstructions (e.g.
  • Page 22: Replacing The Battery Of The Remote Control

    Installation, use and maintenance guide Urban – Urban E FIGURE - 7 FIGURE – FIGURE – FIGURE - 8 8.3 REPLACING THE BATTERY OF THE REMOTE CONTROL When the infrared remote control does not send out the transmission signal (the led comes not on), the battery must be replaced.
  • Page 23 Installation, use and maintenance guide Urban – Urban E Page 22...
  • Page 24: Smoke Discharge Tube And Ventilation Of The Rooms

    Installation, use and maintenance guide Urban – Urban E 9 – SMOKE DISCHARGE TUBE AND VENTILATION OF THE ROOMS 9.1 FOREWORD Due to the frequent accidents caused by poor functioning of flue outlets installed in private dwellings, we have prepared the following paragraph to assist the installer in his inspection of the parts concerned with eliminating the gases produced by combustion.
  • Page 25: Flue Outlet / Flue System Components

    Installation, use and maintenance guide Urban – Urban E 9.3.1 FLUE OUTLET / FLUE SYSTEM COMPONENTS Every chimney must have minimum number of components as laid down by standard UNI EN 10683 which are also indicated in the figure below.
  • Page 26 Installation, use and maintenance guide Urban – Urban E COMIGNOLO E CANNA FUMARIA SECONDO NORMA UNI 10683 LASTRA DI COPERTURA INTERNO ESTERNO LAMIERA DI ACCIAIO A TENUTA STAGNA ISPEZIONE ISPEZIONE It must be possible to inspect and remove all the smoke tube sections for clean-out purposes.
  • Page 27: Alarms

    ATTENTION: The appearance of one of the alarms described below, does not necessarily imply a defect in the product, but simply Thermorossi S.p.A.’s intention to inform the user of the need for corrective actions in order to guarantee maximum safety, greater reliability and high performance of the appliance .
  • Page 28 Installation, use and maintenance guide Urban – Urban E 11 – ELECTRONIC BOARD LEGENDA TERMOSTATO A RIARMO RESET THERMOSTAT PRESSOSTATO PRESSURE SWITCH ASPIRATORE FUMI SMOKE SUCTION UNIT VENTILATORE AMBIENTE ROOM FAN MOTORE COCLEA SCREW FEEDER MOTOR RESISTENZA ACCENSIONE LIGHTING HEATER TERMOSTATO 95°...
  • Page 29 Installation, use and maintenance guide Urban – Urban E 12 – INFORMATION FOR THE SKILLED TECHNICIAN 12.1 MAIN COMPONENTS AND THEIR POSITION SMOKE PRESSURE SWITCH This is a safety switch that stops the screw feeder motor whenever necessary. The main cause for the pressure switch tripping is a blocked flue outlet or smoke exhaust pipe.
  • Page 30 Installation, use and maintenance guide Urban – Urban E 12.3 TROUBLESHOOTING CAUSE-SOLUTION PROBLEM POSSIBLE CAUSE SOLUTION CLEAN THE BRAZIER AS INDICATED IN THIS USE AND PELLET TANK IS EMPTY MAINTENANCE GUIDE, THEN FILL UP THE TANK WITH THE “NO PELLET – CLEAN BURNER” ALARM IS SHOWN ON THE DISPLAY...
  • Page 31 Installation, use and maintenance guide Urban – Urban E PROBLEM POSSIBLE CAUSE SOLUTION CLEAN THE BRAZIER AS INDICATED IN THIS USE AND DELAYED START BECAUSE THE SCREW FEEDER IS EMPTY THE APPLIANCE ENTERS MAINTENANCE GUIDE, THEN FILL UP THE TANK WITH THE “FAILED START –...