Page 1
HEATING TECHNOLOGY AND INNOVATION INSTALLATION, USE AND MAINTENANCE GUIDE ECOTHERM 5000 36011 Arsiero (VI) ITALY - Via Grumolo, 4 - www.thermorossi.com...
Page 2
C O N T E N T S C O N T E N T S C O N T E N T S C O N T E N T S C O N T E N T S DECLARATION OF CONFORMITY INTRODUCTION ....................................
Thermorossi s.p.a, will automatically void the warranty and the manufacturer's responsibility, pursuant to D.P.R. 224 of 24/05/1988, art. 6/b.Use only original Thermorossi spare parts. If the appliance is sold or transferred to another user ensure that the guide is handed over with it.
Page 4
TECHNICAL CHARA TECHNICAL CHARACTERISTICS CTERISTICS CTERISTICS CTERISTICS CTERISTICS * All the data are based on the appliance fuelled with Austrian standard ÖNORM M 7135 type- approved pellets. Ecotherm 5000 Ecotherm 5000 Ecotherm 5000 Easy Metalcolor Ceramic element Height (mm) Depth (mm)
1 52 E C O T H E R M 5000 C E R A M IC A LEGENDA Ecotherm 5000 Easy (In questo modello non è Ecotherm 5000 Easy The lower ceramic panel presente la ceramica inferiore) is not included in this model...
Page 6
4 4 4 4 4 INST INST INSTALLA INST INST ALLA ALLA ALLA ALLATION TION TION TION TION 4 . 1 4 . 1 4 . 1 4 . 1 4 . 1 HEATER L TER L TER L TER L TER LOCA OCATION TION...
Page 7
4 . 1 . 2 4 . 1 . 2 4 . 1 . 2 4 . 1 . 2 4 . 1 . 2 MOUNTING CERAMIC CASING MOUNTING CERAMIC CASING MOUNTING CERAMIC CASING MOUNTING CERAMIC CASING MOUNTING CERAMIC CASING The next step, after positioning the heater, is to mount the ceramic casing as illustrated in the figures below.
5 5 5 5 5 DESCRIPTIONS OF CONTROLS 5 . 1 5 . 1 5 . 1 DESCRIPTION OF CONTR DESCRIPTION OF CONTROL P DESCRIPTION OF CONTR OL P OL P OL PANEL ANEL ANEL ANEL AND HEA AND HEA AND HEA AND HEATER REAR P TER REAR P...
DA A A A A Y Y Y Y Y AND AND TIME SETTING TIME SETTING TIME SETTING TIME SETTING TIME SETTING The heater must be fed with the rear switch in position "1". Display (7) may show the inscriptions On , OFF or Start. To set the time and the day of the week carry out the procedures described below.
Page 10
When the programming is enabled (temporary inscription on cr on the display and, at the same time, a fixed point is present on the right side at the bottom of the display) any additional chronothermostat (see para. 7.2) is deactivated. OPERA OPERA TING LEVEL SETTING...
Page 11
6.3 INFRARED REMO 6.3 INFRARED REMO 6.3 INFRARED REMOTE CONTR TE CONTR TE CONTR TE CONTRO L 6.3 INFRARED REMO 6.3 INFRARED REMO TE CONTR A practical infrared remote control is supplied with the heater: press the left button to adjust the ventilation level, press the right button to adjust the combustion level.
Page 12
AUTO 5 program In program AUTO 5 the room temperature thermostat is enabled. The radio control adjusts the ventilation and the combustion automatically in relation to the target room temperature set in display area (8). The desired room temperature appears in area (8). You can vary the desired room temperature by simply pressing button (3) and/or (4) (variation indicated in area (8)).
Page 13
Non-conformities must be reported within two months of having identified them. Devices or parts returned for replacement become the property of Thermorossi. The presence of irregular black-blue lines on the display (also present when de- energised and battery flat or missing) indicate that the glass screen of the display is damaged following a fall or impact: in this case the breakage is not covered by the guarantee.
"Perry". CAUTION: In the event of connections to the chronothermostat Thermorossi shall not be held responsible for the insert not starting up, smoke leaks, breakage of the lighting component. In the event of a programmed cycle on always ensure that the brazier is clean and seated correctly in its lodging.
Page 15
8 . 2 8 . 2 8 . 2 CLEANING CLEANING AND MAINT CLEANING AND MAINT AND MAINT AND MAINTAINING AINING AINING AINING THE HEA THE HEA THE HEA THE HEATER 8 . 2 8 . 2 CLEANING CLEANING AND MAINT AINING THE HEA •...
Page 18
1, that is, OFF. The batteries are guaranteed for 6 months. Caution: Use only the battery charger provided by Thermorossi. The use of any other type of battery charger will invalidate the product warranty. 8 . 4 8 .
9 . 1 . 1 9 . 1 . 1 COMB COMB USTION USTION AIR INT AIR INT 9 . 1 . 1 9 . 1 . 1 9 . 1 . 1 COMB COMBUSTION COMB USTION USTION AIR INT AIR INT AIR INTAKE The air required for combustion is taken directly from the room in which the heater is installed.
Page 20
ALARMS ALARMS ALARMS ALARMS ALARMS The heater is programmed to communicate 3 fundamental alarms. The alarms are listed below: AL PE : is communicated when the temperature during the On mode drops below 42 °C. This indicates that the heater is switching off due to lack of pellets. AL AC : is communicated if after the start up phase the temperature does not rise above 42°C.
Page 21
INFORMA INFORMA TION FOR TION FOR THE SKILLED THE SKILLED TECHNICIAN TECHNICIAN INFORMA INFORMATION FOR INFORMA TION FOR TION FOR THE SKILLED THE SKILLED THE SKILLED TECHNICIAN TECHNICIAN TECHNICIAN 12.1 MAIN COMPONENTS AND THEIR OPERATION SMOKE PRESSURE SWITCH This is a safety switch that stops the screw feeder motor whenever necessary. The main cause for the pressure switch tripping is a blocked flue outlet or smoke exhaust pipe.
12.3 TROUBLESHOOTING CAUSE-SOLUTION PROBLEM CAUSE SOLUTION PELLET TANK IS EMPTY (DISPLAY SHOWS THE INSCRIPTION AL PE) FILL UP THE TANK FOREIGN BODY SUCH AS NAIL, NYLON, PIECE OF WOOD ON THE FEEDER SCREW ON THE BOTTOM OF THE TANK REMOVE THE FOREIGN BODY ( DISPLAY SHOWS THE INSCRIPTION AL PE) SMOKE EXHAUST NOT FREE, OR WITH TERMINAL THAT OBSTRUCTS THE PASSAGE...
Page 23
INSTALLED I N THE CONTROL PA NEL IS REPLACE THE BATTERY REMAIN IN THE MEMORY EXHAUSTED NEARBY THERE IS ANOTHER THERMOROSSI THE HEATER EXECUTES RANDOM COMMANDS OR HEATER MODEL THERMOCONFORT WITH RANDOMLY VARIES THE VENTILATION LEVEL AND CHANGE THE CODE SELECTOR...
SPARE P ARE P ARE P ARE P ARE PAR ARTS 13.1 SPARE PARTS pg. 24...
Page 25
13.2 SPARE PARTS LEGENDA K E Y Inox Stainless steel Beige Beige Rosso/a Cuoio Leather Nero/a Black Porta completa Complete door Porta ghisa Cast door Vetro Glass Guarnizioni Gaskets Maniglia acciaio Steel handle Semiguscio anteriore Front handle cover Semiguscio posteriore Back handle cover Term.
Page 26
13.3 SPARE PARTS LEGENDA K E Y Condensatore Condenser Thermocomfort Thermocomfort Attizzatoio Riddling tool Cuoio Leather Beige Beige Rosso/a Alto Basso Bottom pg. 26...
Page 27
13.4 SPARE PARTS 7001 2863 A lto - D x 60006470 A T T IZZA T O IO 7001 2864 B asso - D x 7001 2866 A lto - S x 6001 1 766 C uoio 7001 2867 B asso - S x 6001 1 768 B eige 6001 1 764 R ossa 6001 2908 B eige...
Page 28
13.5 SPARE PARTS 7001 3 61 2 7001 3 61 2 7001 3 807 7001 3 61 0 P an n ello 6001 3 1 3 3 T argh etta 6001 2787 B atteria C R 203 2 7001 3 865 7001 3 606 P an n ello 6001 1 750 T erm ostato R iarm o 6001 1 656 In terru ttore 0 - 1...
Need help?
Do you have a question about the ECOTHERM 5000 and is the answer not in the manual?
Questions and answers