15. Troubleshooting
Error or fault pattern
n = ∞
Alarm
TEST
Power
Service
Alarm
TEST
Power
Service
Alarm
TEST
Power
Service
Alarm
TEST
Power
Service
Alarm
TEST
Power
Service
Alarm
TEST
Power
Service
Alarm
TEST
Power
Service
Possible causes
•
Negative power-on self-test
0 The electronics unit is
defective
•
All LEDs are off
•
All LEDs are on continuously
•
No condensate is drained after
pressing the TEST button
•
Condensate is only drained
when the TEST button is
pressed
•
The BEKOMAT
discharges
®
continuously
BEKOMAT
Troubleshooting
•
Contact BEKO TECHNOLOGIES customer
service (see "1.1 Contact" on page 5)
•
Read off the operating voltage on the type
plate and check it
•
Check whether voltage is applied to the
terminals of the control board (GND,
+24 VDC)
•
Check the connection terminals on the
control board
•
Disconnect the product from the voltage
supply and reconnect after > 5 seconds
•
Inspect the circuit board for potential
damage
•
Check the feed line and the drain line
•
Replace the Service-Unit
•
Check the valve function by pressing the
TEST button
0 Valve switching can be heard clearly
(clicking sound)
•
Check the connection terminals on the
control board
•
Install the feed line with a slope > 3 %
•
Check whether the necessary minimum
pressure has been reached (see "4. Technical
data" on page 23)
•
Replace the Service-Unit
•
Replace the Service-Unit
33iU / 33iU CO
®