Original installation and operation manual
Illustration
Alarm
Power
Service
Alarm
TEST
Power
Service
Alarm
Power
Service
Alarm
TEST
Power
Service
Alarm
Power
Service
For further information about fault indications during operation, see "15. Troubleshooting" on page 63.
TEST
n = ∞
Alarm
TEST
Power
Service
TEST
n = ∞
Alarm
TEST
Power
Service
TEST
Description / explanation
Discharge procedure (TEST button pressed briefly)
The red ALARM LED is off
The green POWER LED is on (100 % brightness) while
the solenoid valve is cycling
Pre-alarm (TEST button pressed > 1 minute and
< 5 minutes)
The red ALARM LED flashes
The green POWER LED is on (100 % brightness)
Alarm (TEST button pressed > 5 minutes)
The red ALARM LED is on
The green POWER LED is on (50 % brightness)
Alarm mode (malfunctioning of condensate discharge)
The red ALARM LED flashes
The green POWER LED is on (50 % brightness)
0 The solenoid valve is cycling every 4 minutes
After the malfunction has been eliminated, the
BEKOMAT
automatically switches to normal operation.
®
Maintenance signal
The green POWER LED flashes.
0 Change Service-Units
BEKOMAT