BEKOMAT
®
33iU / 33iU CO
9.2 Operating states
Illustration
Alarm
Power
Service
Alarm
Power
Service
Alarm
TEST
Power
Service
Alarm
TEST
Power
Service
Alarm
TEST
Power
Service
Alarm
Power
Service
42 | 68
TEST
TEST
n = 2
Alarm
TEST
Power
Service
n = 20
Alarm
TEST
Power
Service
n = ∞
Alarm
TEST
Power
Service
TEST
Original installation and operation manual
Description / explanation
Disconnected
•
All LEDs are off
Switch on / power-on self-test
•
All LEDs are on for 1 second
•
The BEKOMAT
carries out a diagnosis of the
®
electronics unit
Positive power-on self-test
number of repetitions n = 2x
•
The red ALARM LED is off
•
The green POWER LED is on (100 % brightness) while
the solenoid valve is cycling
•
The green POWER LED is on (50 % brightness) while
the solenoid valve is not cycling
0 The BEKOMAT
switches to normal operation
®
Negative power-on self-test
number of repetitions n = 20x
•
The red ALARM LED is on
•
The green POWER LED is on (100 % brightness) while
the solenoid valve is cycling quickly
•
The green POWER LED is on (50 % brightness) while
the solenoid valve is not cycling
0 The BEKOMAT
goes into fail-safe operation
®
(continuously loop n = ∞)
•
The solenoid valve is cycling once per second
Ready for operation (normal operating mode)
•
The red ALARM LED is off
•
The green POWER LED is on (50 % brightness)