Download Print this page

Maintenance - U-Line H-3405 Operating Instructions Manual

Electric pallet truck

Advertisement

BATTERY CAPACITY METER
1.
The charge status of the battery is indicated on the
battery capacity meter with ten indicator bars for each
10% increase. With the consumption of battery capacity,
the bars will descend downwards from the top.
(See Figure 6)
Figure 6
Capacity Sufficient
Charge Required
0
1
2. The truck will automatically cut off lifting functions
when the battery reaches 20%.
3. The battery of the pallet truck should be charged
fully and regularly. When "Capacity Insufficient"
alarm flashes on battery capacity meter during
operation, please charge the battery immediately.
MAINTENANCE AND CHARGE OF BATTERY
1. The H-3405 pallet trucks are equipped with a
specific charger to charge the battery. The charger
should be plugged into a standard 120 volt outlet.
CAUTION! Before connecting the charger to
the battery, make sure the emergency shut-off
switch and key switch are in the "OFF" position.
Charge the battery in a dry, well-ventilated
area and keep away from any source of fire.
NOTE: If the truck is not in use, battery charges
should be performed no less than once per
month.
2. Disconnect the battery cable plug from the battery
and attach to the charger. (See Figure 7)
Battery Cable Plug
Figure 7
3. Press the "ON" switch on the charger.
PAGE 4 OF 7
Capacity Insufficient
0
1
0

MAINTENANCE

4. The charger will adjust the current according to
residual capacity of the battery automatically
which ensures the battery is charged correctly.
After charging the battery, the charger indicator
lights turn green and charger stops automatically.
Battery charging generally takes 7-8 hours.
BALANCE CHARGING THE BATTERY
NOTE: With time the battery will need to be
balanced and should be done in accordance with
the maintenance schedule noted in this manual.
1
1. Connect the charger to a standard 120V outlet.
CAUTION! Before connecting the charger to
the battery make sure the emergency shut-off
switch and key switch are in the "OFF" position.
Charge the battery in a dry, well-ventilated
area and keep away from any source of fire.
2. Disconnect the battery cable plug from the battery
and attach to the charger. (See Figure 7)
3. Push the balance button on the charger so it
illuminates.
4. Press the "ON" switch on the charger.
5. The charger will adjust the current according to
residual capacity of the battery automatically,
which ensures the battery is charged correctly.
BATTERY CHECKING AND FILLING PROCEDURE
NOTE: With time, water will evaporate from the
batteries and must be refilled in accordance with
the maintenance schedule noted in this manual.
Figure 8
2
1
1.
Open the watering cap on the battery. (See Figure 8)
2. Make sure the water completely covers the Element
Protector Plate within the battery. (See Figure 8)
3. Add distilled water if necessary. Close the watering cap.
NOTE: Do not overfill the battery. Water level
should be between the plates in the battery and
the bottom of the watering well.
Watering Well
Recommended Water Level
Element Protector Plate
Watering Cap