Summary of Contents for Inter-fab EDGE ANSI/NSPI-5
Page 1
E D G E D I V I N G B O A R D E D G E C O M P O S I T E S P R I N G S E D G E F I B E R G L A S S S T A N D Assembly &...
Page 2
INTER-FAB, INC. 3050 S. ALVERNON WAY TUCSON, AZ 85713 (800) 737-5386 or visit: www.inter-fab.com To obtain complete copies of the ANSI/NSPI-5 2003 Standard for Residential Inground Pools or to obtain copies of the “Plan Your Dive, Steer Up” or “The Sensible Way to Enjoy Your Inground Swimming Pool”...
E D G E ™ D I V I N G S Y S T E M SAFETY FIRST! This Inter-Fab diving board and stand shall be installed only by a professional swimming pool contractor or with the direct supervision of a licensed professional, engineer or architect. Diving boards may be installed only on residential inground swimming pools properly designed for their use.
Page 5
I N S T A L L A T I O N M A N U A L E D G E ™ D I V I N G S Y S T E M SAFETY FIRST! “A pool is the safest place to swim and a diving board installed in compliance with manufacturers instructions and the 2003 ANSI/NSPI Standard for In-ground Residential Pools is the safest place to dive from.
5. Installing any diving board greater than 8’ on any Edge Stand is strictly prohibited. Inter-Fab Edge Diving Boards are designed for use only with the Edge Diving Stand and Edge Composite Spring Set. Edge components are only compatible with other Edge components.
NOTE: WHEN COPING IS USED, DO NOT SET FRONT JIG BOLTS CLOSER THAN 3” FROM THE BACK EDGE OF THE COPING. TABLE 3 – PLACEMENT CHART ADDITIONALLY REFER TO: ANSI/NSPI-5 2003 American National Standard for Residential Inground Swimming Pools and to page 5 for Inter-Fab Residential Inground Pool Minimum Specifications. MIN. MAX HEIGHT EDGE...
The tip of the diving board must be positioned directly over Pt. A as shown on page 5 and according to the ANSI/NSPI-5 2003 Standard and Inter-Fab’s Residential Pool Minimum Specifications Make sure the jig anchor bolts project out of the concrete deck 1-1/2” for the Edge Stand with ample concrete depth below the jig in accordance with Figure A on page 6.
Page 10
I N S T A L L A T I O N M A N U A L E D G E ™ D I V I N G S Y S T E M INSTALLATION INSTRUCTIONS: Continued When finishing the deck surface, maintain a level deck where the jig bolts project out so the dive stand makes uniform contact with the deck surface.
I N S T A L L A T I O N M A N U A L E D G E ™ D I V I N G S Y S T E M EDGE DIVING SYSTEM (EDGE6WW, EDGE-BASE, EDGE-SPRING-GR) DRAWING REPRESENTS THE FOLLOWING PART NUMBERS: EDGE-BASE (shown)
I N S T A L L A T I O N M A N U A L E D G E ™ D I V I N G S Y S T E M SUPPORT INFORMATION: ARTICLE 5 – POOL DIMENSIONS AND TOLERANCES Extracted from ANSI/NSPI- 2003, American National Standard for Residential Inground Swimming Pools EDGE-IM Rev.
Page 13
I N S T A L L A T I O N M A N U A L E D G E ™ D I V I N G S Y S T E M SUPPORT INFORMATION: ARTICLE 5 – POOL DIMENSIONS AND TOLERANCES Extracted from ANSI/NSPI- 2003, American National Standard for Residential Inground Swimming Pools EDGE-IM Rev.
Page 14
I N S T A L L A T I O N M A N U A L E D G E ™ D I V I N G S Y S T E M SUPPORT INFORMATION: ARTICLE 5 – POOL DIMENSIONS AND TOLERANCES Extracted from ANSI/NSPI- 2003, American National Standard for Residential Inground Swimming Pools EDGE-IM Rev.
Page 15
I N S T A L L A T I O N M A N U A L E D G E ™ D I V I N G S Y S T E M SUPPORT INFORMATION: ARTICLE 5 – POOL DIMENSIONS AND TOLERANCES Extracted from ANSI/NSPI- 2003, American National Standard for Residential Inground Swimming Pools EDGE-IM Rev.
Page 16
I N S T A L L A T I O N M A N U A L E D G E ™ D I V I N G S Y S T E M SUPPORT INFORMATION: ARTICLE 5 – POOL DIMENSIONS AND TOLERANCES Extracted from ANSI/NSPI- 2003, American National Standard for Residential Inground Swimming Pools EDGE-IM Rev.
Page 17
I N S T A L L A T I O N M A N U A L E D G E ™ D I V I N G S Y S T E M SUPPORT INFORMATION: ARTICLE 5 – POOL DIMENSIONS AND TOLERANCES Extracted from ANSI/NSPI- 2003, American National Standard for Residential Inground Swimming Pools To obtain complete copies of the ANSI/NSPI-5 2003 Standard for Residential Inground Pools contact:...
Inter-Fab, Inc., and expressly does not cover any labor or reinstallation expenses related to the replacement of any and all Inter-Fab products. This limited warranty shall be the sole and exclusive remedy of irrespective of whether the claims are made in contract, tort, warranty, law, equity or by statue.