enphase IQ 7+ Installation And Operation Manual page 38

Table of Contents

Advertisement

Topic
12
Maximum
microinverters per 20A (max) AC branch circuit
240 VAC (single phase)
208 VAC (single phase)
CEC weighted efficiency
240 VAC (single phase)
208 VAC (single phase)
Static MPPT efficiency (weighted, ref EN 50530)
Total harmonic distortion
Ambient temperature range
Night tare loss
Storage temperature range
Compatibility
Dimensions not including mounting bracket
Connector type
Weight
Environmental category / UV exposure rating
Torque specifications for fasteners
(Do not over torque)
Cooling
Relative humidity range
Approved for wet locations
Pollution degree
Communication
Standard warranty term
Compliance
Grounding
Monitoring
Integrated DC disconnect/
Integrated AC disconnect
12
Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.
.
38
IQ 7 / IQ 7+ / IQ 7X / IQ 7A Micro Installation and Operation
IQ7A-72-2-US Microinverter Parameters
Miscellaneous Parameters
Features and Specifications
Pairs with most 60-cell/120- half-cell and 72-cell/144 half-cell PV
modules
212 mm x 175 mm x 30.2 mm (approximate)
MC-4 connector
1.08 kg (2.38 lbs.)
NEMA type 6 / outdoor
Natural convection - no fans
4% to 100% condensing
Yes
PD3
Power line communication (PLC)
enphase.com/warranty
CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part
15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01
This product is UL Listed as PV Rapid Shut Down Equipment and
conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-
2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC
conductors, when installed according manufacturer's instructions.
The DC circuit meets the requirements for ungrounded PV arrays
in NEC. Ground fault protection (GFP) is integrated into the class
II double insulated microinverter.
Enlighten Manager and MyEnlighten monitoring options. Both
options require an Enphase IQ Envoy
The DC and AC connectors have been evaluated and approved
for use as the load-break disconnect required by NEC 690.
© 2020 Enphase Energy Inc. All rights reserved.
Unit
%
97.0
96.5
%
99.0
%
C
mW
C
6 mm (1/4") mounting hardware: 5 N m (45 - 50 in-lbs.)
8 mm (5/16") mounting hardware: 9 N m (80 - 85 in-lbs.)
When using UL 2703 mounting hardware, use the
manufacturer's recommended torque value
Min
Typical
-40
-40
141-00043-03
Max
11
11
5
+60
60
+85