Topic
AC short circuit fault current over 3 cycles
High AC voltage trip limit accuracy
Low AC voltage trip limit accuracy
Frequency trip limit accuracy
Trip time accuracy
Overvoltage class AC port
AC port backfeed under single fault
Power factor setting
3
Maximum
microinverters per 20A (max) AC branch circuit
240 VAC (single phase)
208 VAC (single phase)
CEC weighted efficiency
240 VAC (single phase)
208 VAC (single phase)
Static MPPT efficiency (weighted, ref EN 50530)
Total harmonic distortion
Ambient temperature range
Night tare loss
Storage temperature range
Compatibility
Dimensions not including mounting bracket
Connector type
Weight
Environmental category / UV exposure rating
Torque specifications for fasteners
(Do not over torque)
Cooling
Relative humidity range
Approved for wet locations
Pollution degree
3
Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.
.
31
IQ 7 / IQ 7+ / IQ 7X / IQ 7A Micro Installation and Operation
Enphase IQ7-60-2-US Microinverter Parameters
Miscellaneous Parameters
Features and Specifications
Pairs with most 60-cell/120 half-cell PV modules.
212 mm x 175 mm x 30.2 mm (approximate)
MC-4 connector
1.08 kg (2.38 lbs.)
NEMA type 6 / outdoor
Natural convection - no fans
4% to 100% condensing
Yes
PD3
© 2020 Enphase Energy Inc. All rights reserved.
Unit
Min
A rms for over 3
cycles
mVrms
mVrms
179
%
±0.1
milliseconds
A
%
%
%
C
-40
mW
C
-40
6 mm (1/4") mounting hardware: 5 N m (45 to 50 in-lbs.)
8 mm (5/16") mounting hardware: 9 N m (80 to 85 in-
lbs.)
When using UL 2703 mounting hardware, use the
manufacturer's recommended torque value
Typical
Max
5.8 Arms
280
±0.1% or 2 cycles
III
0
1.0
16
13
97.0
96.5
99.0
5
+65
50
+85
141-00043-03