Maintenance And Repair; Cleaning And Care; Inspection - Bosch rexroth SYDFE1 2X Series Operating Instructions Manual

Pressure and flow control system
Table of Contents

Advertisement

Maintenance and repair | Pressure and flow control system SYDFE1 series 2X, 3X

10 Maintenance and repair

10.1

CLEANING AND CARE

Solvents and aggressive cleaning agents!
Aggressive cleaning agents may damage the seals of the SYDFE1 control system
and make them age faster.
▶ Never use solvents or aggressive cleaning agents.
Ingress of dirt and liquids!
This will result in the fact that the safe operation of the SYDFE1 control system
can no longer be ensured.
▶ When carrying out any work on the SYDFE1 control system observe strictest
cleanliness.
▶ Do not use high-pressure cleaners.
For cleaning and care of the SYDFE1 control system, observe the following:
▶ Plug all openings with suitable protective caps/devices.
▶ Check that all seals and plugs of the plug-in connections are securely seated to
ensure that no moisture can enter the SYDFE1 control system during cleaning.
▶ Use only water and, if necessary, a mild detergent to clean the SYDFE1 control
system.
▶ Remove external coarse dirt and keep sensitive and important parts like
solenoids, valves and indicators clean.
10.2

INSPECTION

In order that the SYDFE1 control system will work reliably and for a long time,
Rexroth recommends that you inspect the SYDFE1 control system regularly at the
following maintenance intervals and document the following operating conditions:
Table 17: Inspection schedule
Work to be carried out
Hydraulic
system
NOTICE
Check level of hydraulic fluid in the tank.
Check operating temperature (comparable load state).
Analyze quality of the hydraulic fluid.
RE 30011-B, Edition 10.2021, Bosch Rexroth AG
73/96
Interval
Daily
Weekly
Annually or every
2000 h (whichever
occurs first)