Panasonic PT-RZ21К Operating Instructions Manual page 64

Hide thumbs Also See for PT-RZ21К:
Table of Contents

Advertisement

Chapter 3 Basic Operations — Switching on/off the projector
Interrelation of luminance and runtime
The projector can be operated at arbitrary brightness and duration of use by combining the settings of [MAX
LIGHT OUTPUT LEVEL] and [LIGHT OUTPUT].
Interrelation of luminance and runtime is as follows. Make the initial setting (operation setting) depending on your
desired duration of use and brightness of the projected image.
Values of the luminance and runtime are rough estimations.
r To set the projector based on the duration of use
Duration of use (hour)
20 000
24 000
27 000
31 000
35 000
40 000
r To set the projector based on luminance
Luminance (lm)
20 000
18 000
16 000
14 000
12 000
10 000
8 000
6 000
4 000
Note
f Under influence of characteristics of each light source, conditions of use, installation environment, etc., the runtime may be shorter than the
estimation.
f The duration of use is referred to as the runtime when you use the projector successively. The duration of use is an estimated duration and
is not the warranty period.
f The estimated runtime is a time for the luminance to decrease to half.
f If the consolidated runtime of the projector exceeds 20 000 hours, replacement of the components inside the projector may be required. The
consolidated runtime can be confirmed in the [STATUS] screen. Refer to the [PROJECTOR SETUP] menu → [STATUS] for details.
f After completed the initial setting, the wider the combination of luminance and runtime becomes by setting the [PROJECTOR SETUP]
menu → [BRIGHTNESS CONTROL] → [BRIGHTNESS CONTROL SETUP] → [CONSTANT MODE] to [AUTO] or [PC]. Refer to the
[PROJECTOR SETUP] menu → [BRIGHTNESS CONTROL] for details.
64 - ENGLISH
[MAX LIGHT OUTPUT LEVEL]
(%)
100.0
100.0
100.0
100.0
100.0
[MAX LIGHT OUTPUT LEVEL]
(%)
100.0
100.0
100.0
100.0
100.0
[LIGHT OUTPUT] (%)
100.0
100.0
88.4
74.9
64.3
[LIGHT OUTPUT] (%)
100.0
90.0
80.0
70.0
60.0
Luminance (lm)
20 000
20 000
17 600
14 900
12 800
Runtime (hour)
24 290
26 600
29 370
32 730
36 900