The bypass blending valve works as a typical push-
pull bypass valve, but has the added ability to finely
adjust hardness of the treated water leaving the water
softener. If slightly harder water is desired than is
normally output by the water softener, this bypass
blend ing valve can divert a small stream of hard
water before it enters the water softener and blend it
with the exiting softened water. The amount of water
diverted is controlled by turning a blend adjusting
knob on the end cap of the valve stem (See Figure
14).
1. When the bypass valve is in service position (nor-
mal softener operation), with handle pulled all the
way out (See Figure 14), increase hardness of
treated water by turning the blend adjusting knob
counterclockwise up to 6 turns from the fully
closed position. While adjusting this knob, hold
the bypass valve handle to prevent the stem from
rotating.
2. Do not continue to turn the knob counterclock-
wise beyond 6 turns from the fully closed position,
as this would eventually pull the screw's internal
o-rings out of their seat and water would leak from
the bypass valve.
3. Decrease hardness of treated water by turning the
blend adjusting knob clockwise while holding the
bypass handle. When the knob will not turn any
more, hard water is no longer being blended with
treated water.
4. Once the desired hardness is achieved, the adjust-
ment knob may be locked in place by tightening
the hex nut clockwise against the end cap using
an adjustable wrench. Hold the bypass valve
handle to prevent the stem from rotating, or else
use another wrench to grip the stem on the flats
between the end cap and the bypass valve body.
Loosen the hex nut (turn it counterclockwise)
before readjusting the hardness or closing the
diversion path for servicing (see next step)
5. If the water softener is to be serviced or discon-
nected from the bypass valve, the blend adjusting
knob must be turned all the way clockwise to close
the diversion path and prevent water leaking from
the softener valve inlet of the bypass valve.

Bypass Blending Valve

SERVICE POSITION

(Normal Softener Operation)
Soft Water
Pull
Handle
Softener
Valve Outlet
Softener
Valve Inlet
BYPASS POSITION
Hard Water
Push
Handle
7
Out
Hard
Water In
Diverted Hard Water
(controlled by blend
adjusting knob)
Blend Adjusting Knob
Turn counterclockwise to
increase hardness of
treated water (clockwise to
decrease hardness)
Out
Hard
Water In
Hex Nut
Turn clockwise
to lock blend
adjusting knob
(counterclock-
wise to unlock)
Blend Adjusting Knob
If servicing water softener,
turn clockwise as far as it
will go