Page 1
OWNER’S MANUAL How to install, operate and maintain your EcoWater Systems Air Aspirated Iron Filter ETF AIV-10 Models ETF AIV-12 EcoWater Systems LLC Designed, Engineered & P.O. Box 64420, St. Paul, MN 55164-0420 Assembled in the U.S.A. 1-800-86WATER 7336313 (Rev. A 12/10/12)
ECOWATER Specifications & Dimensions S Y S T E M S SPECIFICATIONS Model ETF AIV-10 Model ETF AIV-12 Model Code HAAIF HAAIF Amount of Zeolite Media 1.0 cu. ft. 2.0 cu. ft. Amount of Quartz Gravel 17 lbs. 29 lbs.
ECOWATER Inspect Shipment & Safety Guides S Y S T E M S INSPECT SHIPMENT The parts required to assemble and install the Air Remove and discard (or recycle) all packing materials. Aspirated Iron Filter are included with the unit.
ECOWATER Before Starting Installation S Y S T E M S WHERE TO INSTALL THE FILTER TOOLS, PIPE & FITTINGS, OTHER MATERIALS YOU WILL NEED Place the filter as close as possible to the pressure tank (well system) or water meter (city water).
ECOWATER Typical Installation Illustrations S Y S T E M S INSTALLATION USING ECOWATER BYPASS VALVE CROSS-OVER Use if water supply flows from the left. Filtered Include single or 3-valve bypass. Water OUT UNFILTERED FILTERED WATER Unfiltered WATER Water IN...
ECOWATER Installation S Y S T E M S 1. TURN OFF WATER SUPPLY Clip (2) a. Close the main water supply valve near the well pump or water meter. 1” Copper Tubes (install in b. Shut off the electric or fuel supply to the water...
Page 8
ECOWATER Installation S Y S T E M S b. Place bypass valve(s) into “bypass” position. On a Ground single valve, slide the stem inward to BYPASS Clamp (See Fig. 4 on page 6). On a 3 valve system, close the inlet and outlet valves, and open the bypass valve (See Fig.
ECOWATER Description of Operation & Sanitizing S Y S T E M S DESCRIPTION OF OPERATION Service water enters the filter and passes through air drain, then empties the tank of water, replacing it with captured at the top of the mineral tank. Dissolved air drawn through the aspirator.
ECOWATER Programming the Electronic Controller S Y S T E M S Display UP button DOWN button RECHARGE button SELECT button FIG. 12 CONTROLLER SETTINGS REQUIRED B. SET DAYS BETWEEN RECHARGES upon installation, and after an extended power outage. 1. If you completed the previous step, the word When the transformer is plugged into the electrical “RECHARGE"...
ECOWATER Programming & Controller Features / Options (continued) S Y S T E M S C. SET RECHARGE START TIME 2. The filter’s default recharge start time is 12:00 AM. This is normally a time of day when water is not 1.
Page 12
ECOWATER Controller Features / Options (continued) S Y S T E M S RECHARGE CYCLE TIME ADJUSTMENTS AUXILIARY OUTPUT CONTROL The default setting for backwash and aspirate times The electronic controller’s auxiliary output may be of the recharge cycle are factory set for maximum used to operate various types of external equipment, performance of the filter.
ECOWATER Features / Options & Routine Maintenance (continued) S Y S T E M S Then press the SELECT button to display the screen shown in Fig. 24. FIG. 23 FIG. 24 4. CHEMICAL FEEDER TRIP VOLUME: If you have set the auxiliary output control to CF (Chemical 5.
ECOWATER Troubleshooting S Y S T E M S AUTOMATIC ELECTRONIC DIAGNOSTICS MANUALLY INITIATED ELECTRONIC DIAGNOSTICS This filter has a self-diagnostic function for the electri- cal system. The computer monitors electronic com- Use the following procedures to advance the filter ponents and circuits for correct operation.
Page 15
ECOWATER Troubleshooting (continued) S Y S T E M S RESETTING TO FACTORY DEFAULTS 7. To return to the present time display, press the SELECT button. If the model code was To reset the electronic controller to its factory default changed, make all controller settings.
ECOWATER Troubleshooting Guide & Wiring Schematic S Y S T E M S TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION 1. Riser tube o-ring. 1. Reseat or replace riser o-ring. Iron bleed 2. Over-running filter bed. 2. Increase recharge frequency and backwash time.
7336656 Zeolite Media, 1 cu. ft. 7124415 Gravel, 17 lbs. 7336185 Inlet Check Valve, 1” 7248706 Ground Clamp Kit Not illustrated To order parts, call your local EcoWater dealer or go to www.ecowater.com to locate a dealer in your area.
Page 18
ECOWATER Repair Parts S Y S T E M S VALVE EXPLODED VIEW Flow Plug Assembly Assembled View Wear Strip Seal Cross-section View...
Page 19
Key Nos. 70 & 73) 7077642 Copper Tube, 1” 7271204 1” NPT Threaded Adaptor Ù Optional parts, not included with filter To order parts, call your local EcoWater dealer or go to www.ecowater.com to locate a dealer in your area.
Should you need service, your local, independent EcoWater Dealer is only a phone call away. PHONE:____________________________________________________________ To obtain warranty service, notice must be given, within thirty (30) days of the discovery of the defect, to your local EcoWater Systems dealer.