Removing the PG Sensor and PG Motor
When you remove or install the PG sensor, be careful not to bend the PG motor detection
board.
1.
Remove the connector junction board assembly. (Refer to the previous page.)
2.
Remove the CPS (P) (M3 x 6) screw securing the PG sensor. Then pull the PG
sensor forward and remove it.
3.
Remove the 2 CP (PS) (M3 x 6) screws securing the PG motor and remove the
motor.
CP [Ps] [M3x6]
Figure 3-36. Removing the PG Sensor and PG Motor
transmission gear is between 0.05 and 0.15 mm (almost no backlash).
screw at portion B to thefrume hole, so that the PG sensor is secure.
When you install the PG sensor or PG motor, perform theplaten gap motor value (platen