Removing the Cooling Fan and C117 Power Supply Board Assembly
1.
Remove the bottom panel assembly. (See page 3-17.)
2.
If you need to remove the cooling fan, remove the 4 CCN (M3 x 30) screws
securing it and remove the fan.
3.
Disconnect connectors CN2, CN3, and CN4.
4.
Remove the 6 CPB (M3 x 11) screws and CPN (0) (M3 x 8) screw securing the
Cl 17 power supply board assembly and remove the board.
Figure 3-22. Removing the Cl17 Power Supply Board Assembly