Daikin DV PTC 14 Series Installation Instructions Manual page 16

Table of Contents

Advertisement

SPEED SELECTION DIP SWITCHES
COOL
ADJUST
SELECTION
SELECTION
SWITCHES
SWITCHES
TAP
S1
S2
S3
A
OFF
OFF
OFF
B
ON
OFF
ON
C
OFF
ON
OFF
D
ON
ON
ON
PROFILES
PRE-RUN
A
B
C
D
TO SET AIRFLOW: (1) Select model and desired HIGH STAGE
COOLING AIRFLOW. Determine the corresponding TAP (A, B, C, D). Set
DIP switches S1 and S2 to the appropriate ON/OFF positions.
(2) Select model and installed electric heater size. Set DIP switches S9,
S10 and S11 to the appropriate ON/OFF positions.
(3) If airflow adjustment is required, set TRIM ENABLE SWITCH S8 to ON
(OFF-0% Trim) and set S3 and S4 to appropriate ON/OFF positions. TAP
A is +5%, TAP B is -5%, TAP C is +10%, TAP D is -10%.
TO SET COMFORT MODE: Select desired Comfort Mode Profile (see
profiles above). Set DIP switches S5 and S6 to appropriate ON/OFF
positions.
DEHUMIDIFICATION: To enable, set DIP switch S7 to ON. Cooling airflow
will be reduced to 85% of nominal value during cool call when DEHUM
command is present. To disable, set S7 to OFF.
CONTINUOUS FAN SPEED: Use DIP switches S12 and S13 to select
one of the 4 continuous fan speeds, TAP A is 25%, TAP B is 50%, TAP C
is 75%, TAP D is 100%.
NOTES:
1. Airflow data shown applies to legacy mode operation only. For a
fully communicating system, please see the outdoor unit's installation
instructions for cooling and heat pump airflow data. See Fully
Communicating Daikin System-Airflow Consideration section for details.
2. Airflow blink codes are approximations of actual airflow.
HTR
S9
S10 S11
DV25PTCB14 DV29PTCB14
(kW)
3
ON
ON
ON
550
5
ON
ON OFF
650
6
ON OFF ON
700
8
ON OFF OFF
800
10
OFF ON
ON
850
15
OFF ON OFF
875
19*
OFF OFF ON
NR
20
OFF OFF ON
NR
21
OFF OFF OFF
NR
25*
OFF OFF OFF
NR
Note : Airflow data shown applies to the electric heat only in either legacy mode or communicating mode operation
* Within thermostat user menu will display 20KW for OFF-OFF-ON dip switch selection, 21kW for OFF-OFF-OFF dip switch selection.
21kW for OFF -OFF-OFF dip switch selection.
NR - Not Rated
†† For match up with a 3 ton outdoor unit:
Airflow for 5kW up to 15kW heater kits shall be set to 1300 cfm speed tap of ON-OFF-ON.
††† For match up with a 3.5 ton outdoor unit: Heater kit application shall not exceed 20 kW.
Airflow for 5 kW up to 20 kW heater kits shall be set to 1620 cfm speed tap of ON-OFF-ON.
PROFILE
CONTINUOUS
SELECTION
FAN SPEED
SWITCHES
S4
S5
S6
S12
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
SHORT-RUN
OFF DELAY
----
----
60 SEC. / 100%
----
30 SEC. / 50%
60 SEC. / 100%
----
7.5 MIN. / 82%
60 SEC. / 100%
----
7.5 MIN. / 82%
30 SEC. / 50%
DV35PTCB14
DV33PTCC14 DV39PTCC14 DV49PTCC14 DV37PTCC14 DV59PTCC14 DV37PTCD14 DV59PTCD14 DV49PTCD14 DV61PTCD14 DV31PTCC14
DV37PTCB14
550
550
600
650
650
700
700
700
750
800
800
850
875
875
920
875
1050
950
NR
NR
NR
NR
NR
NR
NR
NR
NR
NR
NR
NR
S13
OFF
OFF
ON
ON
NOTE: Airflow blink codes are approximations of actual airflow. Airflows
provided are at 0.3 static.
NR
NR
NR
700
800
700
770
800
770
880
950
880
970
1090
970
1090
1090
1290
1090
1290
1280
1345
1280
1345
NR
NR
NR
NR
NR
NR
NR
NR
NR
16
COOLING / HEAT PUMP AIRFLOW TABLE
MODEL
Tap
Low Stage
A
410
DV25PTCB14
B
565
DV35PTCB14
C
650
D
685
A
375
DV29PTCB14
B
545
DV37PTCB14
C
630
D
740
A
475
B
565
DV33PTCC14
C
690
D
760
A
665
B
770
DV39PTCC14
C
815
D
910
A
710
B
745
DV49PTCC14
C
880
D
975
A
590
DV31PTCC14
B
705
DV37PTCC14
C
845
D
910
A
610
B
810
DV59PTCC14
C
940
D
1070
A
605
B
725
DV37PTCD14
C
820
D
940
A
1040
B
1260
DV59PTCD14
C
1330
D
1395
A
820
B
895
DV49PTCD14
C
995
D
1056
A
1080
B
1210
DV61PTCD14
C
1280
D
1350
NR
NR
NR
800
870
990
800
970
1110
950
1060
1200
1120
1240
1220
1520
NR
NR
NR
1250
1520
NR
NR
NR
NR
NR
NR
High Stage
610
840
970
1020
610
795
930
1085
690
785
980
1110
990
1150
1095
1225
955
1005
1180
1310
880
1055
1265
1360
875
1225
1410
1595
900
1080
1225
1405
1445
1790
1890
1990
1195
1320
1460
1530
1630
1820
1925
2025
NR
NR
600
950
1030
700
1060
1150
770
1150
1250
880
1220
1320
970
1520
1650
1090
NR
NR
1280
NR
1690
NR
NR
1750
NR
NR
1750
NR

Hide quick links: