Installing Cable; Connections In Nexus Network - Furuno FI-304 Operator's Manual

Fi-30 series compass data
Table of Contents

Advertisement

2.1.1

Installing cable

The power cable is connected via a 3A fuse from the battery or at the boats fuse panel
and direct to the instrument or Server. One red and one black power wire is included.
Note, Set C71 ON (see 5.4.1).
Always connect a 3 AMP fuse between Power supply and instrument.
Screen
Black
Red
3A Fuse
2.1.2

Connections in Nexus Network

If you already have a Nexus Network i.e. a Server, it is more practical to connect the
transducer to the Server due to the single instrument cable installation. Note, Set C71
OFF (see 5.4.1).
Server
The instrument is then connected to the Server's Nexus Network terminal (pin 5, 6, 7
and 8) or at any FI-30 instruments terminal .
From FI-30 Server or other
FI-30 instrument
Green
Yellow
White
11
Transducer
Transducer

Advertisement

Table of Contents
loading

Table of Contents