Triple output power supply/charger

Advertisement

Quick Links

AL400UL3
AL400UL3X
Triple Output Power Supply/Charger
Installation Guide
For a red enclosure add an "R" suffix to the part #, e.g. AL400UL3XR
Altronix Corp.
140 58th St. Brooklyn, NY
LISTED
More than just power.
Rev. 030619
TM
Installing Company: _______________ Service Rep. Name: __________________________________
Address: _____________________________________________ Phone #: __________________

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AL400UL3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Altronix AL400UL3

  • Page 1 AL400UL3 AL400UL3X Triple Output Power Supply/Charger Installation Guide For a red enclosure add an “R” suffix to the part #, e.g. AL400UL3XR Altronix Corp. 140 58th St. Brooklyn, NY LISTED More than just power. Rev. 030619 Installing Company: _______________ Service Rep. Name: __________________________________...
  • Page 2 Overview: Altronix AL400UL3/AL400UL3X multi-output power supply/charger is specifically designed for use with access control, burglar alarm, fire and nurse call systems and accessories. AL400UL3/AL400UL3X converts a 115VAC 60Hz input into three (3) individual power-limited outputs (see specifications). Features: Agency Listings: LED Indicators: •...
  • Page 3: Installation Instructions

    Note: Maximum charging current under discharge is 0.7A. Note: Expected battery life is 5 years, however it is recommended changing batteries in 4 years or less if needed. AL400UL3 / AL400UL3X Installation Guide - 3 -...
  • Page 4: Led Diagnostics

    24VDC from power supply (AL400ULXB2). + 24VDC – 24VDC @ 1.5A continuous power-limited output + 12VDC – 12VDC @ 1.75A continuous power-limited output. + 5VDC – 5VDC @ 1.75A continuous power-limited output. - 4 - AL400UL3 / AL400UL3X Installation Guide...
  • Page 5 Do not expose to rain or moisture. Earth Ground 5VDC 115VAC 12VDC power mains non power- limited Class 1 24VDC AC Delay + DC – + BAT – Battery connection non power-limited Battery 1 Battery 2 AL400UL3 / AL400UL3X Installation Guide - 5 -...
  • Page 6: Appendix A - Ul Listed Compatible Devices

    Appendix A - UL Listed Compatible Devices –––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– A.1 Four (4) Wire Smoke Detectors Table A-1 below lists four (4) wire smoke detectors compatible with AL400UL3/AL400UL3X output. System Sensor Max Stand-by Alarm Current Detector Type Smoke Detector/Base Current (mA) (mA)
  • Page 7 0.75” 0.75” 12.5” (317.5mm) 1.20” 1.20” (19.1mm) (19.1mm) (30.5mm) (30.5mm) 11.0” (279.4mm) 0.9375” (23.8mm) 1.40” 1.40” (35.6mm) (35.6mm) 0.9375” (23.8mm) 3.25” (82.6mm) 3.25” (82.6mm) 1.0” (25.4mm) 1.0” 1.0” 10.5” (266.7mm) (25.4mm) (25.4mm) AL400UL3 / AL400UL3X Installation Guide - 7 -...
  • Page 8 1.5” 4.615” (117.2mm) 4.615” (117.2mm) (38.1mm) (38.1mm) Altronix is not responsible for any typographical errors. –––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty IIAL400UL3/AL400UL3X G06U...