Do you have a question about the Eco 250esm and is the answer not in the manual?
Questions and answers
Patrick Willems
March 31, 2025
No more warm water. And we think also lime. We are looking for someone in our region (= Belgium West Flanders city : Tielt 8700) who can work on this system.
Eco 250esm / 300esm / 280i / 200p 1. IMPORTANT • In spaces that are potentially explosive due to vapour or liquid gases. The Eco shall only be started if the hot water cylinder is fully Do not turn on the solar system: filed with water.
Eco 250esm / 300esm / 280i / 200p 3. DESCRIPTION After passing through the panel, the Klea fluid is aspirated by the system’s mechanical component, the compressor, which in turn The Eco solar system is equipment based on raises the temperature and pressure; it is...
Eco 250esm / 300esm / 280i / 200p 4. TECHNICAL SPECIFICATIONS The connections to the panel are Flare SAE (screw) types: The thermodynamic solar system Eco is composed by the following components: - 3/8’’ Aspiration (upper connection) - 1/4’’ Liquid (lower connection)
Eco 250esm / 300esm / 280i / 200p The front part of the block has two valves, of 2 and 3 ways destined for the panel connections (3/8'' - Aspiration; 1/4'' - liquid) Expansion valve Flange Fig. 5 Hot water cylinder Fig.
Eco 250esm / 300esm / 280i / 200p return path of hot water, emptying of the hot NOTE: water tank and raised temperatures. It is a Installation of the expansion tank is the valve body made out of chromed brass, in responsibility of the installer.
Eco 250esm / 300esm / 280i / 200p Side B Side A Fig. 13 Panel types (left and right) Fig. 11 Panel fixing diagram 5.2 Hot Water Cylinder Installation The system comes with six sets of: profiles, The hot water cylinder shall be installed in a screws, nuts, washers, wall plugs.
Eco 250esm / 300esm / 280i / 200p other on the block’s support structure DHP according to the ISO1337 standards (compressor or flange) and verify that no and EN12735). continuity actually exists. Piping Diameters - The Thermodynamic Block is coupled into...
Page 11
Eco 250esm / 300esm / 280i / 200p The conic must not have any barbs or After finished the connection, it must prove imperfections. The longitude of the walls of that no gas escape exists by applying soap the conic one must be uniform.
Eco 250esm / 300esm / 280i / 200p The piping must be properly insulated with a 5.5 Nitrogen Load flexible insulation sleeve made from (Armaflex type) elastomeric foam in order to After connections been concluded guarantee prevent any possible condensation brought that there is no leakage.
Eco 250esm / 300esm / 280i / 200p between solar panel The Eco is equipped with an electrical thermodynamic block. For situations that this resistance heating process in case of any length is exceed is necessary to have to eventual system breakdown. If it is make adjustments of the load.
Page 14
Eco 250esm / 300esm / 280i / 200p 6 CONTROL PANEL You may start up the Eco if all instructions have been accomplished. The rise up of the water temperature from 10ºC to 55ºC may vary between 2 and 10 hours depending on the model of the solar system and the outside conditions.
Eco 250esm / 300esm / 280i / 200p 7 ANOMALIES / CAUSES / SOLUTIONS ANOMALY CAUSE SOLUTION Verify the presence of 230 V A/C at The water is cold and the compressor system input source. does not function. Check that the system is turned on.
Eco 250esm / 300esm / 280i / 200p Technical Support Notes: - Melted Compressor fuse; start-up condenser capacity must be checked. - Melted RES fuse; the possibility of a short-circuit must be verified (e.g. electrical resistance). - Safety thermostat operational; electronic panel parameters must be checked.
Page 17
Eco 250esm / 300esm / 280i / 200p 9 TECHNICAL DATA Eco 280i / 200p System Eco 250esm / 300esm UNITS Potential Data 1690 – 2900 Thermal Power 390 – 550 Absorbed Power 1200 Electric Support Power Compressor Hermetic / Piston...
Eco 250esm / 300esm / 280i / 200p Electrical Schematic Eco 250esm / 300esm / 280i / 280p Sonda 1 11 12 Legenda T – Safety Thermostat (75ºC) Electronic Electrónico T - Termóstato de segurança (75ºC) C – Compressor C- Compressor R – Resistance R- Resistência LP – Low Pressure Switch ...
Page 23
NOTE: This sheet should remain with the manual, for the customer. The following sheet shall be completed and must be returned to Energie est, Lda.
Need help?
Do you have a question about the Eco 250esm and is the answer not in the manual?
Questions and answers
No more warm water. And we think also lime. We are looking for someone in our region (= Belgium West Flanders city : Tielt 8700) who can work on this system.