Download Print this page

General Directions For Installation - Videx VK4K/6358 Series Installation Handbook

“6 wire” bus one way, two way videokit

Advertisement

VK4K/6358 Series "6 wire Bus" videokit

General directions for installation

CONNECTION TO MAINS
The system must be installed according to national rules in force, in particular we recommend to:
• Connect the system to the mains through an all-pole circuit breaker which shall have contact separation of at least 3mm in each
pole and shall disconnect all poles simultaneously;
• The all-pole circuit breaker shall be placed for easy access and the switch shall remain readily operable.
POWER SUPPLY INSTALLATION
• Remove the terminal side covers by unscrewing the retaining screws;
• Fix the power supply to a DIN bar or directly to the wall using two expansion type screws;
• Switch off the mains using the circuit breaker mentioned above and then make the connections as shown on the installation diagrams;
• Check the connections and secure the wires into the terminals;
• Replace the terminal covers and fix them using the relevant screws;
• After completing the wiring, double check all connections then restore the mains.
CABLE SIZE
Video connections and Audio connections must be wired in twisted pair: pair the video lines (terminals/signals V1 and V2), pair
the audio lines (terminals /signals 1 and 2).
IMPORTANT NOTE: SOLID COPPER CABLES MUST BE USED. COPPER COATED STEEL (CCS) AND COPPER COATED
ALUMINIUM (CCA) CAN NOT BE USED ON THE SYSTEM.
Distance Suggested cables type
Up to
CAT5/CAT6
40mt
FTP/UTP/CW1308
AWG24/0.22mm
* Double up the two wires to increase
the cross section and reduce the re-
sistance.
Power
supply
2 wires
Ø 1mm2
20mt max
Distance Suggested cables type
Up to
4 pair (8 cores) 0.35mm2
50mt
AWG22 - 48Ω/Km
From
3 pair (6 cores) 0.8mm2
50 to
AWG18 - 19.2Ω/Km
100mt
From
4 pair (8 cores) 0.8mm2
100 to
AWG18 - 19.2Ω/Km
200mt
VK4K/6358 Series - Installation handbook
Power
supply
2 wires
2
Ø 1mm2
20mt max
Videophone
Videophone
"+V" and "–"
Ø 0.35mm2
"1" and "2"
Ø 0.35mm2 Twisted pair
"V1" and "V2"
Ø 0.35mm2 Twisted pair
Up to 50mt
"+V" and "–"
Ø 0.75mm2
"1" and "2"
Ø 0.5mm2 Twisted pair
"V1" and "V2"
Ø 0.5mm2 Twisted pair
from 50 to 100mt
"+V" and "–"
Ø 1.5mm2
"1" and "2"
Ø 0.75mm2 Twisted pair
"V1" and "V2"
Ø 0.75mm2 Twisted pair
from 100 to 200mt
- 6 -
BROWN
WHITE/BROWN
BLUE
WHITE/BLUE
ORANGE
WHITE/ORANGE
GREEN
WHITE/GREEN
Up to 40mt
+V
Outdoor
1
station
2
V1
V2
+V
1
2
V1
V2
66251400-EN - V5.1 - 31/08/20
+V *
– *
Outdoor
1
station
2
V1
V2
Outdoor
station
+V
Outdoor
1
station
2
V1
V2

Advertisement

loading