Advertisement

Quick Links

ES30/30 / M30/30ES
Installation/Operator Manual
WARNING: For your safety the information
in this manual must be followed to
minimize the risk of fire or explosion and
to prevent property damage, personal
injury or death.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your
building.
Clear the room, building or area of
all occupants.
Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
— Installation and service must be
performed by a qualified installer, service
agency or the gas supplier.
AVERTISSEMENT: Assurez-vous de bien
suivre les instructions données dans cette
notice pour réduire au minimum le risque
d'incendie ou d'explosion ou pour éviter
tout dommage matériel, toute blessure ou
la mort.
—Ne pas entreposer ni utiliser d'essence
ni d'autres vapeurs ou liquides
inflammables à proximité de cet
appareil ou de tout autre appareil.
—QUE FAIRE SI VOUS SENTEZ UNE
ODEUR DE GAZ:
Ne pas tenter d'allumer d'appareils.
Ne touchez à aucun interrupteur. Ne
pas vous servir des téléphones se
trouvant dans le bâtiment.
Évacuez la pièce, le bâtiment ou la
zone.
Appelez immédiatement votre
fournisseur de gaz depuis un voisin.
Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le
fournisseur de gaz, appelez le service
des incendies.
—L'installation et l'entretien doivent être
assurés par un installateur ou un
service d'entretien qualifié ou par le
fournisseur de gaz.
American Dryer Corporation
88 Currant Road
Fall River MA 02720-4781 USA
Telephone: +1 (508) 678-9000 / Fax: +1 (508) 678-9447
e-mail: techsupport@amdry.com
www.adclaundry.com
ADC Part No. 112809-6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ES30/30 and is the answer not in the manual?

Questions and answers

Summary of Contents for ADC ES30/30

  • Page 1 ES30/30 / M30/30ES Installation/Operator Manual AVERTISSEMENT: Assurez-vous de bien WARNING: For your safety the information suivre les instructions données dans cette in this manual must be followed to notice pour réduire au minimum le risque minimize the risk of fire or explosion and d’incendie ou d’explosion ou pour éviter...
  • Page 2 Replacement parts can be obtained from your reseller or the ADC factory. When ordering replacement parts from the factory, you can FAX your order to ADC at +1 (508) 678-9447 or telephone your order directly to the ADC Parts Department at +1 (508) 678-9000.
  • Page 3: Table Of Contents

    WARNING In the State of Massachusetts, the following installation instructions apply: Proposition 65 Installations and repairs must be performed Use of this product could expose you to substances by a qualified or licensed contractor, from fuel combustion that contain chemicals plumber, or gasfitter qualified or licensed by the State of Massachusetts.
  • Page 4: Safety Precautions

    Safety Precautions ____________________ The possible presence of residual quantities of aggressive or decomposed chemicals in the load may produce damage Warning to the machine and harmful fumes. A program should be established for the inspection and For your safety, the information in this manual cleaning of lint in the burner area, exhaust ductwork, and must be followed to minimize the risk of fire or area around the back of the dryer.
  • Page 5 The “cool down” cycle of tumble dryers should be used to reduce the temperature of the items. They should not be removed from the tumble dryer or piled or stacked while hot. NOTES ______________________________________________________ Fabric softeners or similar products should not be used in a tumbler dryer to eliminate the effects of static electricity unless _____________________________________________________________ this practice is specifically recommended by the manufacturer...
  • Page 6: Specifications

    Specifications _______________________________________________________________________ 13.61 kg MAXIMUM CAPACITY 30 lb (DRY WEIGHT) PER POCKET TUMBLER DIAMETER 25-3/4” 65.41 cm TUMBLER DEPTH 34” 86.36 cm 290.25 L TUMBLER VOLUME 10-1/4 cu ft PER POCKET 0.19 kW TUMBLER/DRIVE MOTOR 1/4 hp PER POCKET BLOWER/FAN MOTOR 1/2 hp 0.37 kW PER POCKET...
  • Page 7 Specifications _______________________________________________________________________ NOTE: The manufacturer reserves the right to make changes in specifications at any time without notice or obligation. 112809 - 6 www.adclaundry.com...
  • Page 8: Installation Procedures

    Installation Procedures _______________ Unpacking / Setting Up ________________ Installation should be performed by competent professional Remove protective shipping material (i.e., plastic wrap and in accordance with local, state, and country codes. In the optional shipping box) from the dryer. absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.1-LATEST IMPORTANT: Dryer must be transported and handled in an EDITION (National Fuel Gas Code) or ANSI/NFPA NO.
  • Page 9: Fresh Air Supply Requirements

    Fresh Air Supply Requirements _______ Exhaust Requirements ________________ This appliance may only be installed in a room that meets Exhaust ductwork should be designed and installed by a the appropriate ventilation requirements specified in the qualified professional. Improperly sized ductwork will create national installation regulations.
  • Page 10 Outside Ductwork Protection The length of the ductwork from the dryer to the outside exhaust outlet, must not exceed 20 feet (6.10 meters). The minimum To protect the outside end of the horizontal ductwork from the diameter of this ductwork must be at least 8-inches (20.32 weather, a 90°...
  • Page 11: Electrical Information

    Electrical Information _________________ Warning (Gas Models Only) Electrical Requirements Dryers built for use with a voltage between 200 and 230/240 must verify the input voltage during All electrical connections must be made by a properly licensed installation. If the nominal voltage is outside of the and competent electrician.
  • Page 12 IMPORTANT: For personal safety and proper operation, the Input connection wiring must be sized properly to handle the dryer must be grounded. dryer’s current draw. This information is printed on the dryer’s data label. Provisions are made for ground connection in each dryer at the electrical service connection area.
  • Page 13: Gas Information

    Gas Information _______________________ NOTE: Undersized gas piping will result in ignition problems, slow drying, increased use of energy, and can It is your responsibility to have all plumbing connections, create a safety hazard. materials, and workmanship conform to local and state regulations or codes of the country of destination.
  • Page 14: Converting From One Family Of Gas To Another

    The following conversion allows the dryer to be operated with either propane, butane, or LPG. The use of gas valve kit (ADC P/N 140414) disables the internal regulator of the gas valve. Therefore, the gas supply is ungoverned and an external regulator must be provided at the source of the supply (example L.P.
  • Page 15 Disconnect electrical power to the dryer. Repeat these steps for the other burner. Close all shutoff valves (for both top and bottom tumbler) in Affix L.P. Conversion Label (ADC P/N 114515) to the dryer’s dryer’s gas supply line. data label.
  • Page 16: Gas Pressure Testing

    Gas Pressure Testing _________________ Connect the union and the three electrical plugs. Repeat these steps for the other burner. For proper operation, the gas pressure must be correct, consistent and maintained at the gas pressure rates shown Open all shutoff valves, reconnect electrical power to the dryer, on page 13.
  • Page 17 Steam Coil pH Level The steam supply line to the dryer must include a 12-inch (30.48 cm) riser along with a drip trap and check valve. This The normal pH level for copper type steam coils must be will prevent any condensate from entering the steam coil. maintained between a value of 8.5 to 9.5.
  • Page 18: Water Information

    Water Information _____________________ The water connection for the manual bypass is made to the “cross” or “four way” fitting, which has a 3/8” F.N.P.T. and a Before You Start coupling must be used to provide the minimum 1/2-inch (12.7 Check Local Codes and Permits mm) supply (feed) line.
  • Page 19: Preoperational Instructions

    Coin Models When a gas dryer is first started (during initial start-up), it has a tendency not to ignite on the first ignition attempt. This is Microprocessor Controller (Computer) because the gas supply piping is filled with air, so it may take a few minutes for the air to be purged from the lines.
  • Page 20: Service / Parts Information

    Shipping charges are not the responsibility of ADC. All returns Warranty should be “prepaid” to the factory. Any “C.O.D.” or “COLLECT”...
  • Page 21: Routine Maintenance

    Routine Maintenance _________________ 90 Days Cleaning Remove lint from gas valve burner area with a dusting brush or vacuum cleaner attachment. A program and/or schedule should be established for Clean any lint accumulation in and around the motor(s) casing periodic inspection, cleaning, and removal of lint from various opening.
  • Page 22: Data Label Information

    Data Label Information _______________ CE Label Standard Label When contacting ADC, the information on the data label is required to ensure proper service/parts assistance. The data label is located at the upper left rear of the dryer behind the back guard.
  • Page 23: Programming

    Programming __________________________ Event Codes Defined: Top Pocket / Bottom E1 / E4: While attempting to turn on the burner, no burner return Enter Service Mode by Inserting Key and Turning Clockwise signal was received within RADIANT SENSOR COOL DOWN TIME. Main Service Mode window will appear and offer 5 selections: 1: Machine Info 2: Program Setup...
  • Page 24 ADC Part No. 112809 6 - 10/21/14...

This manual is also suitable for:

M30/30es

Table of Contents