AP-51xx Access Point Product Reference Guide
10. Rotate the AP-5131 chassis 45 degrees counter-clockwise. The clips click as they fasten to
the T-bar.
11. The AP-5131 is ready to configure. For information on an AP-5131 default configuration, see
Getting Started on page
System Configuration on page
NOTE If the AP-5131 is utilizing remote management antennae, a wire cover

2.7.4 Above the Ceiling (Plenum) Installations

An AP-5131 above the ceiling installation requires placing the AP-5131 above a suspended ceiling
and installing the provided light pipe under the ceiling tile for viewing the rear panel status LEDs of
the unit. An above the ceiling AP-5131 installation enables installations compliant with drop ceilings,
suspended ceilings and industry standard tiles from .625 to .75 inches thick.
NOTE The AP-5131 is Plenum rated to UL2043 and NEC1999 to support above
3-1. For specific details on AP-5131 system configurations, see
4-1.
can be used to provide a clean finished look to the installation. Contact
Symbol for more information.
the ceiling installations.