Cabinet Mount - Samsung NV75K3340RS User & Installation Manual

Built-in oven
Table of Contents

Advertisement

Installation

Cabinet mount

If installing the oven in a built-in cabinet, the cabinet must have its plastic surfaces
and adhesive parts resistant up to 90 °C, and adjacent furniture must be resistant
up to 75 °C. Samsung is not responsible for damage to furniture from the oven's
heat emission.
The oven must be properly ventilated. For ventilation, leave a gap of about 50 mm
between the lower shelf of the cabinet and the supporting wall. If you install the
oven under a cooktop, follow the cooktop's installation instructions.
Required Dimensions for Installation
B
C
A
D
E
L
K
G
F
J
H
I
8 English
NV75K3340RS_EU_DG68-00750A-01_EN.indd 8
Oven (mm)
A
560
G
Max. 506
B
175
H
Max. 494
C
370
I
21
D
Max. 50
J
545
E
595
K
572
F
595
L
550
Built-in cabinet (mm)
A
B
A
C
B
C
D
D
E
NOTE
The built-in cabinet must have vents (E) to
E
ventilate heat and circulate the air.
Under-sink cabinet (mm)
A
B
A
B
C
D
C
D
NOTE
The built-in cabinet must have vents (D) to
ventilate heat and circulate the air.
Min. 550
Min. 560
Min. 50
Min. 590 - Max. 600
Min 460 x Min. 50
Min. 550
Min. 560
Min. 600
Min 460 x Min. 50