Replacing Brushes

Note: Follow proper Lockout / Tagout procedures prior to cleaning or performing
maintenance on any part of the machine.
On the material entry side, remove the trantorque bushing, 2-bolt hole flange bearings,
bottom brush height adjustment plate, bolt and nut and top and bottom cover plates.
(Figure 22)
On the gearbox side, remove the top and bottom locking collars. (Figure 22A)
Slide the top brush out and remove the old brush and replace with a new brush and re-
attach the trantorque bushing.
Slide the bottom brush out and remove the old brush and replace with a new brush.
Slide the new bottom brush into place and secure it to the gearbox via the locking collar.
Slide the new top brush into place and secure it to the gearbox via the locking collar.
Replace the top and bottom cover plates followed by the 2-bolt flange bearings and the
bottom brush height adjustment plate, bolt and nuts.
Set top and bottom brush height per instructions on pages 16 & 17.
Flange bearing
Flange bearing
Figure 22
Baker M6 DeDuster - Rev 1,
Trantorque bushing
Cover plates
Bottom brush
height adjustment
plate, bolt and nut
11/07;
WWW.BAKER-ONLINE.COM
22
Gearbox locking collar
Gearbox locking collar
Figure 22A