Installing Your Stove
Getting Ready (Continued)
Pellet Venting
C
Adding bends in the exhaust path restricts air flow,
reduces performance and provides a collection
point for ash deposits requiring more frequent
cleaning.
CAUTION
•
Do not connect to any air distribution duct or system
•
Do not install a flue damper in the exhaust venting system of this
Stove
•
Do not connect this Stove to a chimney flue serving another Stove
•
The structural integrity of the manufactured home floor, wall and
ceiling/roof must be maintained
REQUIRED:
Use only 3" or 4" type "L" or "PL" pellet pipe.
Pro Tip
This Stove can be installed with a 3 to 6 inch (76-152mm) Top Vent Offset Adapter Kit. The
3 to 6 inch (76-152mm) Top Vent Offset Adapter are tested to use 24 gauge single wall flue
connector or Listed double wall flue connector to Class A Listed metal chimneys, or masonry
chimneys meeting International Conference of Building Officials (ICBO) standards for solid
fuel Stoves.
Installation Video
Visit pelprostoves.com or scan this code:
pelprostoves.com