Pelpro PP130-B Owner's Manual page 14

Hide thumbs Also See for PP130-B:
Table of Contents

Advertisement

Test Instruction Recommendations: PP130-B
Created on/by: 03/20/18; C. Winslow Howe – HHT Design Engineer
Purpose: To create repeatability in test protocol of the stove.
Hopper Fuel: Hopper of the unit should be loaded up with a full 3 bags of fuel (Each bag weighing 40lb)
Test Settings: Unit should be set up using a 6in flue and 115VAC power source,
High: Dial should be set to 10 and the trim pot should be set to +4. When the unit is set and running at
this setting the light above the dial control will Flash 5 times with a pause between each sequence
Medium: Dial should be set to 3 and the trim pot should be set to +3 When the unit is set and running at
this setting the light above the dial control will flash 2 times with a pause between each sequence.
Low: Dial should be set to 1 and the trim pot should be set to 0. When the unit is set and running at this
setting the light above the dial control will flash once with a pause between each flash.
High
Medium
1445 North Hwy, Colville, WA 99114; 800-234-2508
14 of 112