http://getMANUAL.com
1-9. Notes on Service
1-9. Notes on Service
1-9-1. Power Circuit Breaker
Excessive current in the internal circuitry will trip the circuit breaker, then the power turns off automati-
cally. Check the circuit to eliminate the cause for which the excessive current flows.Press the button
shown in the figure and the power will be turned on.
1-9-2. Notes on Replacement of V Shoe
When fastening the V shoe to the main chassis, be sure to adjust the mounting position with precisely.The
mounting position of the V shoe on the CA-702/P affects the connected position of the DVW-700/
700WS/700P/700WSP, DNV-5 or DNW-7/90/90WS/7P/90P/90WSP.Be sure to tighten the three screws
in order of 1 to 3 as shown in the figure. [Tightening torque: 0.53 ± 0.07 N.m (5.3 ± 0.7 kgf.cm)]
After replacement is completed, check the specification is met.
Specification: a _ b = 0 ± 0.1 mm
a
b
1
3
2
1-17(E)
CA-702
CA-702P